 浏览型号ATH016A0X43-SR的Datasheet PDF文件第10页浏览型号ATH016A0X43-SR的Datasheet PDF文件第11页浏览型号ATH016A0X43-SR的Datasheet PDF文件第12页浏览型号ATH016A0X43-SR的Datasheet PDF文件第13页浏览型号ATH016A0X43-SR的Datasheet PDF文件第15页浏览型号ATH016A0X43-SR的Datasheet PDF文件第16页浏览型号ATH016A0X43-SR的Datasheet PDF文件第17页浏览型号ATH016A0X43-SR的Datasheet PDF文件第18页  
Data Sheet  
Austin SuperlynxTM II SMT Non-isolated Power Modules:  
June 21, 2008  
2.4 – 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 16A output current  
Remote Sense  
Feature Descriptions (continued)  
The Austin SuperLynxTM SMT power modules have a  
Remote Sense feature to minimize the effects of  
distribution losses by regulating the voltage at the  
Remote Sense pin (See Figure 32). The voltage between  
the Sense pin and Vo pin must not exceed 0.5V.  
Voltage Sequencing  
Austin SuperLynxTM II series of modules include a  
sequencing feature, EZ-SEQUENCE that enables users  
to implement various types of output voltage sequencing  
in their applications. This is accomplished via an  
additional sequencing pin. When not using the  
sequencing feature, either tie the SEQ pin to VIN or leave  
it unconnected.  
The amount of power delivered by the module is defined  
as the output voltage multiplied by the output current (Vo  
x Io). When using Remote Sense, the output voltage of  
the module can increase, which if the same output is  
maintained, increases the power output by the module.  
Make sure that the maximum output power of the module  
remains at or below the maximum rated power. When  
the Remote Sense feature is not being used, connect the  
Remote Sense pin to the output pin.  
When an analog voltage is applied to the SEQ pin, the  
output voltage tracks this voltage until the output reaches  
the set-point voltage. The SEQ voltage must be set  
higher than the set-point voltage of the module. The  
output voltage follows the voltage on the SEQ pin on a  
one-to-one volt basis. By connecting multiple modules  
together, customers can get multiple modules to track  
their output voltages to the voltage applied on the SEQ  
pin.  
Rdistribution Rcontact  
Rcontact Rdistribution  
VIN(+)  
VO  
Sense  
RLOAD  
For proper voltage sequencing, first, input voltage is  
applied to the module. The On/Off pin of the module is  
left unconnected (or tied to GND for negative logic  
modules or tied to VIN for positive logic modules) so that  
the module is ON by default. After applying input voltage  
to the module, a minimum of 10msec delay is required  
before applying voltage on the SEQ pin. During this time,  
potential of 50mV (± 10 mV) is maintained on the SEQ  
pin. After 10msec delay, an analog voltage is applied to  
the SEQ pin and the output voltage of the module will  
track this voltage on a one-to-one volt bases until output  
reaches the set-point voltage. To initiate simultaneous  
shutdown of the modules, the SEQ pin voltage is lowered  
in a controlled manner. Output voltage of the modules  
tracks the voltages below their set-point voltages on a  
one-to-one basis. A valid input voltage must be  
maintained until the tracking and output voltages reach  
ground potential.  
Rdistribution Rcontact  
Rcontact Rdistribution  
CO M  
CO M  
Figure 32. Remote sense circuit configuration  
When using the EZ-SEQUENCETM feature to control  
start-up of the module, pre-bias immunity feature during  
start-up is disabled. The pre-bias immunity feature of the  
module relies on the module being in the diode-mode  
during start-up. When using the EZ-SEQUENCETM  
feature, modules goes through an internal set-up time of  
10msec, and will be in synchronous rectification mode  
when voltage at the SEQ pin is applied. This will result in  
sinking current in the module if pre-bias voltage is present  
at the output of the module. When pre-bias immunity  
during start-up is required, the EZ-SEQUENCETM feature  
must be disabled. For additional guidelines on using EZ-  
SEQUENCETM feature of Austin SuperLynxTM II, contact  
the Lineage Power technical representative for  
preliminary application note on output voltage sequencing  
using Austin Lynx II series.  