欢迎访问ic37.com |
会员登录 免费注册
发布采购

ATH010A0X43 参数 Datasheet PDF下载

ATH010A0X43图片预览
型号: ATH010A0X43
PDF下载: 下载PDF文件 查看货源
内容描述: 2.4 - 5.5V直流输入; 0.75Vdc到3.63Vdc输出; 10A的输出电流 [2.4 - 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 10A output current]
分类和应用:
文件页数/大小: 19 页 / 588 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号ATH010A0X43的Datasheet PDF文件第11页浏览型号ATH010A0X43的Datasheet PDF文件第12页浏览型号ATH010A0X43的Datasheet PDF文件第13页浏览型号ATH010A0X43的Datasheet PDF文件第14页浏览型号ATH010A0X43的Datasheet PDF文件第16页浏览型号ATH010A0X43的Datasheet PDF文件第17页浏览型号ATH010A0X43的Datasheet PDF文件第18页浏览型号ATH010A0X43的Datasheet PDF文件第19页  
Data Sheet  
Austin LynxTM II SIP Non-isolated Power Modules:  
March 12, 2009  
2.4 – 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 10A output current  
Thermal Considerations  
25.4_  
(1.0)  
Wind Tunnel  
PWBs  
Power modules operate in a variety of thermal  
environments; however, sufficient cooling should always  
be provided to help ensure reliable operation.  
Power Mod ule  
Considerations include ambient temperature, airflow,  
module power dissipation, and the need for increased  
reliability. A reduction in the operating temperature of  
the module will result in an increase in reliability. The  
thermal data presented here is based on physical  
measurements taken in a wind tunnel. The test set-up  
is shown in Figure 35. Note that the airflow is parallel to  
the long axis of the module as shown in figure 34. The  
derating data applies to airflow in either direction of the  
module’s long axis.  
76.2_  
(3.0)  
x
Probe Location  
for measuring  
airflow and  
ambient  
8.3_  
(0.325)  
Airflow  
temperature  
Air  
flow  
Figure 35. Thermal Test Set-up.  
Top View  
Tref  
Figure 34. T  
ref  
Temperature measurement location.  
The thermal reference point, Tref used in the  
specifications is shown in Figure 34. For reliable  
operation this temperature should not exceed 115 oC.  
The output power of the module should not exceed the  
rated power of the module (Vo,set x Io,max).  
Please refer to the Application Note “Thermal  
Characterization Process For Open-Frame Board-  
Mounted Power Modules” for a detailed discussion of  
thermal aspects including maximum device  
temperatures.  
Heat Transfer via Convection  
Increased airflow over the module enhances the heat  
transfer via convection. Thermal derating curves  
showing the maximum output current that can be  
delivered at different local ambient temperature (TA) for  
airflow conditions ranging from natural convection and  
up to 2m/s (400 ft./min) are shown in the Characteristics  
Curves section.  
LINEAGE POWER  
15  
 复制成功!