Data Sheet
Austin LynxTM II 12V SIP Non-isolated Power Modules:
March 30, 2008
8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current
Design Considerations (continued)
Safety Considerations
Output Filtering
For safety agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards,
i.e., UL 60950-1, CSA C22.2 No. 60950-1-03, and VDE
0850:2001-12 (EN60950-1) Licensed.
The Austin LynxTM II SIP module is designed for low
output ripple voltage and will meet the maximum output
ripple specification with 1 µF ceramic and 10 µF
tantalum capacitors at the output of the module.
However, additional output filtering may be required by
the system designer for a number of reasons. First,
there may be a need to further reduce the output ripple
and noise of the module. Second, the dynamic
response characteristics may need to be customized to
a particular load step change.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power
module has extra-low voltage (ELV) outputs when all
inputs are ELV.
The input to these units is to be provided with a fast-
acting fuse with a maximum rating of 15A in the positive
input lead.
To reduce the output ripple and improve the dynamic
response to a step load change, additional capacitance
at the output can be used. Low ESR polymer and
ceramic capacitors are recommended to improve the
dynamic response of the module. For stable operation
of the module, limit the capacitance to less than the
maximum output capacitance as specified in the
electrical specification table.
LINEAGE POWER