Data Sheet
October 17, 2011
9-36V ProLynx
TM
: Non-isolated DC-DC Power Modules
9 – 36Vdc input; 3Vdc to 18Vdc output; 3A to 1.5A output current
Electrical Specifications
(continued)
Parameter
Output Voltage Set-point
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions until end of life)
Adjustment Range (elected by an external resistor)
(Some output voltages may not be possible
depending on the input voltage – see Feature
Descriptions Section)
Output Regulation
Line (V
IN
=V
IN, min
to V
IN, max
)
Load (I
O
=I
O, min
to I
O, max
)
Temperature (T
ref
=T
A, min
to T
A, max
)
Remote Sense Range
Output Ripple and Noise on nominal output
(V
IN
=V
IN, nom
and I
O
=I
O, min
to I
O, max
Co = 0.1μF // 10
μF
ceramic capacitors)
Vout=3.3V, Vin=28V
Peak-to-Peak (5Hz to 20MHz bandwidth)
RMS (5Hz to 20MHz bandwidth)
Vout=18V, Vin=28V
Peak-to-Peak (5Hz to 20MHz bandwidth)
RMS (5Hz to 20MHz bandwidth)
External Capacitance
ESR
≥
1 mΩ
ESR
≥
10 mΩ
With the Tunable Loop
ESR
≥
0.15 mΩ
ESR
≥
10 mΩ
Output Current
Vo=3V
Vo=5V
Vo=12V
Vo=18V
Output Current Limit Inception (Hiccup Mode )
Output Short-Circuit Current
(V
O
≤250mV)
( Hiccup Mode )
Efficiency (I
O
=I
O, max ,
V
O
= V
O,set)
V
IN
= 12Vdc, T
A
=25°C
V
IN
= 12Vdc, T
A
=25°C
V
IN
= 28Vdc, T
A
=25°C
V
IN
= 28Vdc, T
A
=25°C
Switching Frequency
V
O, set
= 3.3Vdc
V
O, set
= 5Vdc
V
O,set
= 12Vdc
V
O,set
= 18Vdc
All
η
η
η
η
fsw
⎯
93.2
95.5
96.0
97.0
300
⎯
%
%
%
%
kHz
TM
1
TM
Device
All
All
Symbol
V
O, set
V
O, set
Min
-2
-2.5
Typ
Max
+2
Unit
% V
O, set
% V
O, set
⎯
+2.5
All
V
O
3
18
Vdc
All
All
All
All
⎯
⎯
⎯
0.4
0.4
0.4
0.5
% V
O, set
% V
O, set
% V
O, set
Vdc
All
All
All
All
38
12
116
38
mV
pk-pk
mV
rms
mV
pk-pk
mV
rms
Without the Tunable Loop
All
All
All
All
C
O, max
C
O, max
C
O, max
C
O, max
0
0
0
0
0
0
0
0
⎯
⎯
⎯
⎯
47
100
100
2000*
3
2.5
2
1.5
μF
μF
μF
μF
All
I
o
Adc
All
All
I
O, lim
I
O, s/c
200
1
% I
o,max
A
rms
1
Depending on Input and Output Voltage, external capacitors require using the new Tunable Loop feature to ensure that
TM
the module is stable as well as getting the best transient response. See the Tunable Loop section for details.
TM
* Larger values may be possible at specific output voltages. Please consult your Lineage Technical representative for
additional details.
LINEAGE
POWER
3