 浏览型号APXS006A0X-25SRZ的Datasheet PDF文件第1页浏览型号APXS006A0X-25SRZ的Datasheet PDF文件第3页浏览型号APXS006A0X-25SRZ的Datasheet PDF文件第4页浏览型号APXS006A0X-25SRZ的Datasheet PDF文件第5页浏览型号APXS006A0X-25SRZ的Datasheet PDF文件第6页浏览型号APXS006A0X-25SRZ的Datasheet PDF文件第7页浏览型号APXS006A0X-25SRZ的Datasheet PDF文件第8页浏览型号APXS006A0X-25SRZ的Datasheet PDF文件第9页  
Data Sheet  
12V Pico TLynxTM 6A: Non-isolated DC-DC Power Modules  
4.5 – 14Vdc input; 0.59Vdc to 5.5Vdc output; 6A output current  
September 4, 2009  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are  
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in  
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for  
extended periods can adversely affect the device reliability.  
Parameter  
Device  
Symbol  
Min  
Max  
Unit  
Input Voltage  
All  
VIN  
-0.3  
15  
Vdc  
Continuous  
Sequencing Voltage  
Operating Ambient Temperature  
(see Thermal Considerations section)  
Storage Temperature  
APTS  
All  
VSEQ  
TA  
-0.3  
-40  
-40  
-55  
ViN  
85  
Vdc  
°C  
-D version  
All  
TA  
105  
125  
°C  
Tstg  
°C  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Parameter  
Device  
All  
Symbol  
VIN  
Min  
Typ  
Max  
14.0  
6.5  
Unit  
Vdc  
Adc  
Operating Input Voltage  
Maximum Input Current  
(VIN=4.5V to 14V, IO=IO, max  
4.5  
All  
IIN,max  
)
VO,set = 0.6 Vdc  
VO,set = 3.3Vdc  
IIN,No load  
IIN,No load  
16  
55  
mA  
mA  
Input No Load Current  
(VIN = 12.0Vdc, IO = 0, module enabled)  
Input Stand-by Current  
(VIN = 12.0Vdc, module disabled)  
All  
All  
IIN,stand-by  
I2t  
1.2  
mA  
A2s  
Inrush Transient  
1
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 1μH source impedance; VIN =0 to  
14V, IO= IOmax ; See Test Configurations)  
All  
All  
86  
50  
mAp-p  
dB  
Input Ripple Rejection (120Hz)  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an  
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included;  
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies  
require a fast-acting fuse with a maximum rating of 6A (see Safety Considerations section). Based on the information  
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating  
can be used. Refer to the fuse manufacturer’s data sheet for further information.  