Data Sheet
16V Pico TLynxTM 4A: Non-isolated DC-DC Power Modules
8 – 16Vdc input; 0.6Vdc to 8.0Vdc output; 4A output current
September 13, 2010
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
All
VIN
-0.3
18
Vdc
Up to 10 seconds
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
All
All
TA
-40
-55
85
°C
°C
Tstg
125
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
All
Symbol
VIN
Min
Typ
Max
16.0
6.5
Unit
Vdc
Adc
Operating Input Voltage
Maximum Input Current
(VIN=8V to 16V, IO=IO, max
8.0
⎯
All
IIN,max
)
V
O,set = 0.6 Vdc
IIN,No load
IIN,No load
18
mA
mA
Input No Load Current
(VIN = 16.0Vdc, IO = 0, module enabled)
VO,set = 8.0Vdc
96.1
Input Stand-by Current
(VIN = 16.0Vdc, module disabled)
All
All
IIN,stand-by
I2t
1.2
mA
A2s
Inrush Transient
1
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN =0 to
16V, IO= IOmax ; See Test Configurations)
All
All
50
mAp-p
dB
Input Ripple Rejection (120Hz)
-46
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated
part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve
maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a
maximum rating of 6 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s
data sheet for further information.
LINEAGE POWER
2