Data Sheet
September 9, 2009
16V Pico TLynx
TM
4A: Non-isolated DC-DC Power Modules
8 – 16Vdc input; 0.6Vdc to 8.0Vdc output; 4A output current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute
stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those
given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can
adversely affect the device reliability.
Parameter
Input Voltage
Up to 10 seconds
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
All
T
stg
-55
125
°C
All
T
A
-40
85
°C
Device
All
Symbol
V
IN
Min
-0.3
Max
18
Unit
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and
temperature conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
=8V to 16V, I
O
=I
O, max
)
Input No Load Current
(V
IN
= 16.0Vdc, I
O
= 0, module enabled)
Input Stand-by Current
(V
IN
= 16.0Vdc, module disabled)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN
=0 to
16V
,
I
O
= I
Omax
; See Test Configurations)
Input Ripple Rejection (120Hz)
V
O,set
= 0.6 Vdc
V
O,set
= 8.0Vdc
All
All
All
All
I
IN,No load
I
IN,No load
I
IN,stand-by
It
50
-46
2
Device
All
All
Symbol
V
IN
I
IN,max
Min
8.0
Typ
⎯
Max
16.0
6.5
Unit
Vdc
Adc
mA
mA
mA
18
96.1
1.2
1
As
mAp-p
dB
2
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included;
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 6 A (see Safety Considerations section). Based on the information
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating
can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE
POWER
2