Data Sheet
12V Micro TLynxTM: Non-isolated DC-DC Power Modules
September 8, 2009
4.5 – 14Vdc input; 0.69Vdc to 5.5Vdc output; 12A output current
achieved by using the Tunable LoopTM feature
described later in this data sheet.
Safety Considerations
For safety agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards,
i.e., UL 60950-1, CSA C22.2 No. 60950-1-03, and VDE
0850:2001-12 (EN60950-1) Licensed.
70
1x10uF External Cap
1x47uF External Cap
60
2x47uF External cap
4x47uF External Cap
50
40
30
20
10
0
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power
module has extra-low voltage (ELV) outputs when all
inputs are ELV.
The input to these units is to be provided with a fast-
acting fuse with a maximum rating of 15A in the positive
input lead.
0.5
1.5
2.5
3.5
4.5
5.5
Output Voltage(Volts)
Figure 41. Output ripple voltage for various output
voltages with external 1x10 µF, 1x47 µF, 2x47 µF or
4x47 µF ceramic capacitors at the output (12A load).
Input voltage is 12V.
LINEAGE POWER