 浏览型号APTS050A0X3-SRPHDZ的Datasheet PDF文件第7页浏览型号APTS050A0X3-SRPHDZ的Datasheet PDF文件第8页浏览型号APTS050A0X3-SRPHDZ的Datasheet PDF文件第9页浏览型号APTS050A0X3-SRPHDZ的Datasheet PDF文件第10页浏览型号APTS050A0X3-SRPHDZ的Datasheet PDF文件第12页浏览型号APTS050A0X3-SRPHDZ的Datasheet PDF文件第13页浏览型号APTS050A0X3-SRPHDZ的Datasheet PDF文件第14页浏览型号APTS050A0X3-SRPHDZ的Datasheet PDF文件第15页  
Data Sheet  
GigaTLynxTM SMT Non-isolated Power Modules:  
4.5 – 14Vdc input; 0.7Vdc to 2.0Vdc, 50A Output  
September 7, 2011  
output reaches the set-point voltage. To initiate  
simultaneous shutdown of the modules, the SEQ pin  
voltage is lowered in a controlled manner. The output  
voltage of the modules tracks the voltages below their  
set-point voltages on a one-to-one basis. A valid input  
voltage must be maintained until the tracking and output  
voltages reach ground potential.  
When using the EZ-SEQUENCETM feature to control  
start-up of the module, pre-bias immunity during start-up  
is disabled. The pre-bias immunity feature of the module  
relies on the module being in the diode-mode during  
start-up. When using the EZ-SEQUENCETM feature,  
modules goes through an internal set-up time of 10msec,  
and will be in synchronous rectification mode when the  
voltage at the SEQ pin is applied. This will result in the  
module sinking current if a pre-bias voltage is present at  
the output of the module. When pre-bias immunity during  
start-up is required, the EZ-SEQUENCETM feature must  
be disabled. For additional guidelines on using the EZ-  
SEQUENCETM feature please contact the Lineage Power  
technical representative for additional information.  
condition. To ensure that all modules come up  
simultaneously, the on/off pins of all paralleled  
converters should be tied together and the  
converters enabled and disabled using the on/off pin.  
The share bus is not designed for redundant  
operation and the system will be non-functional upon  
failure of one of the unit when multiple units are in  
parallel. In particular, if one of the converters shuts  
down during operation, the other converters may  
also shut down due to their outputs hitting current  
limit. In such a situation, unless a coordinated restart  
is ensured, the system may never properly restart  
since different converters will try to restart at different  
times causing an overload condition and subsequent  
shutdown. This situation can be avoided by having  
an external output voltage monitor circuit that detects  
a shutdown condition and forces all converters to  
shut down and restart together.  
When not using the active load share feature, share pins  
should be left unconnected.  
Power Good  
Active Load Sharing (-P Option)  
The Giga TLynxTM modules provide a Power Good  
(PGOOD) signal to indicate that the output voltage is  
within the regulation limits of the power module. The  
PGOOD signal will be de-asserted to a low state if any  
condition such as overtemperature, overcurrent or loss of  
regulation occurs that would result in the output voltage  
going ±12.5% outside the setpoint value. The PGOOD  
terminal is internally pulled-up and provides a voltage of  
~5V, when asserted, thus eliminating the need for an  
external source and pull-up resistor. Additional external  
drive capability can be provided to the PGOOD terminal  
by using a source less than 5V and a suitable pull-up  
resistor to keep the overall external current below 4.5mA  
For additional power requirements, the Giga TLynxTM  
power module is also available with a parallel option. Up  
to five modules can be configured, in parallel, with active  
load sharing.  
Good layout techniques should be observed when using  
multiple units in parallel. To implement forced load  
sharing, the following connections should be made:  
The share pins of all units in parallel must be  
connected together. The path of these connections  
should be as direct as possible.  
All remote-sense pins should be connected to the  
power bus at the same point, i.e., connect all the  
SENSE(+) pins to the (+) side of the bus. Close  
proximity and directness are necessary for good  
noise immunity  
Tunable Loop  
The Giga TLynxTM modules have a new feature that  
optimizes transient response of the module called  
Some special considerations apply for design of  
converters in parallel operation:  
Tunable LoopTM  
.
When sizing the number of modules required for  
parallel operation, take note of the fact that current  
sharing has some tolerance. In addition, under  
transient conditions such as a dynamic load change  
and during startup, all converter output currents will  
not be equal. To allow for such variation and avoid  
the likelihood of a converter shutting off due to a  
current overload, the total capacity of the paralleled  
system should be no more than 90% of the sum of  
the individual converters. As an example, for a  
system of four Giga TLynxTM converters in parallel,  
the total current drawn should be less that 90% of (4  
x 50A) , i.e. less than 180A.  
External capacitors are usually added to the output of the  
module for two reasons: to reduce output ripple and  
noise (see Fig. 23) and to reduce output voltage  
deviations from the steady-state value in the presence of  
dynamic load current changes. Adding external  
capacitance however affects the voltage control loop of  
the module, typically causing the loop to slow down with  
sluggish response. Larger values of external capacitance  
could also cause the module to become unstable.  
The Tunable LoopTM allows the user to externally adjust  
the voltage control loop to match the filter network  
connected to the output of the module. The Tunable  
LoopTM is implemented by connecting a series R-C  
between the SENSE and TRIM+ pins of the module, as  
shown in Fig. 28. This R-C allows the user to externally  
All modules should be turned on and off together.  
This is so that all modules come up at the same time  
avoiding the problem of one converter sourcing  
current into the other leading to an overcurrent trip  
LINEAGE POWER  
11