Data Sheet  
TLynxTM: Non-isolated DC-DC Power Modules:  
January 26, 2010  
2.4 – 5.5Vdc input; 0.6Vdc to 3.63Vdc output; 20A output current  
Feature Descriptions  
Remote On/Off  
VIN+  
The TLynxTM modules feature an On/Off pin for remote  
On/Off operation. Two On/Off logic options are  
available. In the Positive Logic On/Off option, (device  
code suffix “4”- see Ordering Information), the module  
turns ON during a logic High on the On/Off pin and turns  
OFF during a logic Low. With the Negative Logic  
On/Off option, (no device code suffix, see Ordering  
Information), the module turns OFF during logic High  
and ON during logic Low. The On/Off signal is always  
referenced to ground. For either On/Off logic option,  
leaving the On/Off pin disconnected will turn the module  
ON when input voltage is present.  
MODULE  
PTC  
Rpullup  
I
6.34K  
ON/OFF  
ON/OFF  
+
470  
PWM Enable  
V
ON/OFF  
Q1  
3.09K  
GND  
_
For positive logic modules, the circuit configuration for  
using the On/Off pin is shown in Figure 38. When the  
external transistor Q1 is in the OFF state, the On/Off pin  
is pulled high internally and the module is ON. When  
transistor Q1 is turned ON, the On/Off pin is pulled low  
and the module is OFF.  
Figure 39. Circuit configuration for using negative  
On/Off logic.  
Overcurrent Protection  
VIN+  
MODULE  
To provide protection in a fault condition, the unit is  
equipped with a thermal shutdown circuit. The unit will  
shutdown if the overtemperature threshold of 144oC is  
exceeded at the thermal reference point Tref . The  
thermal shutdown is not intended as a guarantee that  
the unit will survive temperatures beyond its rating.  
Once the unit goes into thermal shutdown it will then  
wait to cool before attempting to restart.  
6.34K  
20K  
470  
PWM Enable  
I
ON/OFF  
+
Q2  
ON/OFF  
Q1  
V
ON/OFF  
Input Undervoltage Lockout  
_
At input voltages below the input undervoltage lockout  
limit, the module operation is disabled. The module will  
begin to operate at an input voltage above the  
undervoltage lockout turn-on threshold.  
GND  
Figure 38. Circuit configuration for using positive  
On/Off logic.  
For negative logic On/Off modules, the circuit  
configuration is shown in Fig. 39. The On/Off pin should  
be pulled high with an external pull-up resistor  
(suggested value for the 2.4V to 5.5Vin range is  
8.2Kohms). When transistor Q1 is in the OFF state, the  
On/Off pin is pulled high and the module is OFF. The  
On/Off threshold for logic High on the On/Off pin  
depends on the input voltage and its minimum value is  
Output Voltage Programming  
The output voltage of the TLynxTM module can be  
programmed to any voltage from 0.6dc to 3.63Vdc by  
connecting a resistor between the Trim+ and GND pins  
of the module. Certain restrictions apply on the output  
voltage set point depending on the input voltage. These  
are shown in the Output Voltage vs. Input Voltage Set  
Point Area plot in Fig. 40. The Upper Limit curve shows  
that the entire output voltage range is available with the  
maximum input voltage of 5.5V. The Lower Limit curve  
shows that for output voltages of 1.8V and higher, the  
input voltage needs to be larger than the minimum of  
2.4V.  
VIN – 1.6V. To turn the module ON, Q1 is turned ON  
pulling the On/Off pin low.  
Overcurrent Protection  
To provide protection in a fault (output overload)  
condition, the unit is equipped with internal  
current-limiting circuitry and can endure current limiting  
continuously. At the point of current-limit inception, the  
unit enters hiccup mode. The unit operates normally  
once the output current is brought back into its specified  
range.  