 浏览型号APTH003A0X4-SRZ的Datasheet PDF文件第1页浏览型号APTH003A0X4-SRZ的Datasheet PDF文件第3页浏览型号APTH003A0X4-SRZ的Datasheet PDF文件第4页浏览型号APTH003A0X4-SRZ的Datasheet PDF文件第5页浏览型号APTH003A0X4-SRZ的Datasheet PDF文件第6页浏览型号APTH003A0X4-SRZ的Datasheet PDF文件第7页浏览型号APTH003A0X4-SRZ的Datasheet PDF文件第8页浏览型号APTH003A0X4-SRZ的Datasheet PDF文件第9页  
Data Sheet
September 9, 2009
Pico TLynx
TM
3A: Non-isolated DC-DC Power Modules
2.4 – 5.5Vdc input; 0.6Vdc to 3.63Vdc output; 3A output current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Sequencing Voltage
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
All
T
stg
-55
125
°C
APTH
All
V
SEQ
T
A
-0.3
-40
V
iN, Max
85
Vdc
°C
Device
All
Symbol
V
IN
Min
-0.3
Max
6
Unit
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
=2.4V to 5.5V, I
O
=I
O, max
)
Input No Load Current
(V
IN
= 5.0Vdc, I
O
= 0, module enabled)
Input Stand-by Current
(V
IN
= 5.0Vdc, module disabled)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN
=0 to
5.5V
,
I
O
= I
Omax
; See Test Configurations)
Input Ripple Rejection (120Hz)
All
All
All
It
25
40
2
Device
All
All
V
O,set
= 0.6 Vdc
V
O,set
= 3.3Vdc
All
Symbol
V
IN
I
IN,max
I
IN,No load
I
IN,No load
I
IN,stand-by
Min
2.4
Typ
Max
5.5
3.5
Unit
Vdc
Adc
mA
mA
mA
26
75
2.1
1
As
mAp-p
dB
2
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included;
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 5A (see Safety Considerations section). Based on the information
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating