LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only
Page 7/7
PART NO. LSR9033/TR2
Reliability Test:
Reference
Standard
Classification
Test Item
Test Condition
1.Ta=Under Room Temperature As Per Data Sheet
Maximum Rating.
2.If=20mA
MIL-STD-750D: 1026
MIL-STD-883D: 1005
JIS C 7021: B-1
Operating Life Test
3.t=1000 hrs (-24hrs, +72hrs)
High Temperature
Storage Test
1.Ta=105℃±5℃
2.t=1000 hrs (-24hrs, +72hrs)
MIL-STD-883D:1008
JIS C 7021: B-10
Endurance
Test
Low Temperature
Storage Test
1.Ta=-40℃±5℃
2.t=1000 hrs (-24hrs, +72hrs)
JIS C 7021: B-12
High Temperature
High Humidity
Storage Test
1.Ta=65℃±5℃
2.RH=90 %~95%
3.t=1000hrs ±2hrs
MIL-STD-202F:103B
JIS C 7021: B-11
1.Ta=105℃±5℃&-40℃±5℃
MIL-STD-202F: 107D
MIL-STD-750D: 1051
MIL-STD-883D: 1011
(10min)
(10min)
Thermal Shock Test
Solderability Test
2.total 10 cycles
MIL-STD-202F: 208D
MIL-STD-750D: 2026
MIL-STD-883D: 2003
IEC 68 Part 2-20
1.T.Sol=235 ℃±5℃
2.Immersion time 2 ±0.5sec
3.Coverage ≧95% of the dipped surface
JIS C 7021: A-2
Environmental
Test
MIL-STD-202F: 107D
MIL-STD-750D: 1051
MIL-STD-883D: 1010
JIS C 7021: A-4
1.105℃~25℃ ~-55℃~25℃
30mins 5mins 30mins 5mins
2.10 Cyeles
Temperature
Cycling
1.T=260°C Max. 10sec.Max.
2. 6 Min
MIL-STD-750D:2031.2
J-STD-020
IR Reflow