LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only
PART NO. L9UG9S53/TR1
Reliability Test:
Page 7/7
Classification
Test Item
Test Condition
1.Ta=Under Room Temperature As Per Data Sheet
Maximum Rating.
2.If=20mA
3.t=1000 hrs (-24hrs, +72hrs)
Reference
Standard
MIL-STD-750D: 1026
MIL-STD-883D: 1005
JIS C 7021: B-1
Operating Life Test
High Temperature
Storage Test
Endurance
Test
Low Temperature
Storage Test
1.Ta=105
℃±
5
℃
2.t=1000 hrs (-24hrs, +72hrs)
MIL-STD-883D:1008
JIS C 7021: B-10
1.Ta=-40
℃±
5
℃
2.t=1000 hrs (-24hrs, +72hrs)
JIS C 7021: B-12
High Temperature
High Humidity
Storage Test
1.IR-Reflow In-Board, 2 Times
2.Ta=65
℃±
5
℃
3.RH=90 %~95%
4.t=1000hrs
±
2hrs
1.IR-Reflow In-Board,2 times
2.Ta=105
℃±
5
℃
&
-40
℃±
5
℃
(10min) (10min)
3.total 10 cycles
1.T.Sol=235
℃±
5
℃
2.Immersion time 2
±
0.5sec
3.Immersion rate 25
±
2.5mm/sec
4.Immersion rate 25
±
2.5mm/sec
5.Coverage
≧
95% of the dipped surface
1.105
℃
~
25
℃
~
55
℃
~
25
℃
30mins 5mins 30mins 5mins
2.10 Cyeles
MIL-STD-202F:103B
JIS C 7021: B-11
Thermal Shock Test
MIL-STD-202F: 107D
MIL-STD-750D: 1051
MIL-STD-883D: 1011
MIL-STD-202F: 208D
MIL-STD-750D: 2026
MIL-STD-883D: 2003
IEC 68 Part 2-20
JIS C 7021: A-2
MIL-STD-202F: 107D
MIL-STD-750D: 1051
MIL-STD-883D: 1010
JIS C 7021: A-4
Solderability Test
Environmental
Test
Temperature
Cycling
Solderability Test
Ramp-up rate(183
℃
to Peak) +3
℃
second max
Temp. maintain at 125(
±
25)
℃
120 seconds max
Temp. maintain above 183
℃
60-150 seconds
Peak temperature range 235
℃
+5-0
℃
Time within 5
℃
of actual Peak Temperature(tp)
10-30 seconds
Ramp-down rate +6
℃
/second max
MIL-STD-750D:2031.2
J-STD-020