2. Absolute Maximum Ratings
The following are maximum values which, if exceeded, may cause faulty operation or damage to the unit.
Table 1. ABSOLUTE MAXIMUM RATINGS
Values
Parameter
Symbol
Units
Notes
Min
-0.3
0
Max
+5.5
50
VLCD
TOP
TST
Vdc
¶C
GY\G± YG¶j
Power Input Voltage
Operating Temperature
Storage Temperature
Operating Ambient Humidity
Storage Humidity
1
1
1
1
-20
10
60
¶C
HOP
HST
90
%RH
%RH
10
90
Note : 1. Temperature and relative humidity range are shown in the figure below.
Wet bulb temperature should be 39 ¶C Max, and no condensation of water.