LM201W01
Liquid Crystal Display
Product Specification
3-3. Signal Timing Specifications
This is the signal timing required at the input of the User connector. All of the interface signal timing should be
satisfied with the following specifications for it’s proper operation.
Table 6. Timing Table
ITEM
Symbol
Min
Typ
Max
Unit
ns
Note
Period
tCLK
-
16.8
59.5
16.8
59.5
16.8
59.5
DCLK
2pixel/clk
Frequency
MHz
Period
tHP
fH
920
920
920
tCLK
KHz
Frequency
64.674
64.674
64.674
Hsync
Vsync
Width
tWH
tVP
fV
16
16
16
tCLK
tHP
Hz
Period
1080
1080
1080
Frequency
Width
59.883
59.883
59.883
tWV
6
840
40
6
840
40
6
840
40
tHP
Horizontal Valid
tHV
tHBP
tHFP
-
Horizontal Back Porch
Horizontal Front Porch
Horizontal Blank
Vertical Valid
tCLK
24
24
24
DE
80
80
80
(Data
tVV
tVBP
tVFP
-
1050
21
1050
21
1050
21
Enable)
Vertical Back Porch
Vertical Front Porch
Vertical Blank
tHP
3
3
3
30
30
30
Notes: Hsync period and Hsync width-active should be even number times of tCLK. If the value is odd number
times of tCLK, display control signal can be asynchronous. In order to operate this LCM a Hsync,
Vsyn, and DE(data enable) signals should be used.
1. The performance of the electro-optical characteristics may be influenced by variance of the vertical
refresh rates.
2. Vsync and Hsync should be keep the above specification.
3. Hsync Period, Hsync Width, and Horizontal Back Porch should be any times of of character
number(8).
4. The polarity of Hsync, Vsync is not restricted.
13 / 29
Ver. 0.1
Jun. 06. 2005