LG Semicon
GM71C4403C
DC Electrical Characteristics (VCC = 5V+/-10%, TA = 0 ~ 70C)
Symbol
Parameter
Min
Unit Note
Max
V
OH
Output Level
“H”
2.4
V
CC
V
Output
Output Level
“L”
Level Voltage (IOUT = -5mA)
V
OL
0
0.4
V
Output
Level Voltage (IOUT = 4.2mA)
ICC1
OperatingCurrent
Average Power Supply Operating Current
(RAS, CAS, Address Cycling: tRC = tRC min)
60ns
70ns
80ns
-
-
-
110
100
90
mA 1, 2
ICC2
Standby Current (TTL)
Power Supply Standby Current
(RAS, CAS= VIH, DOUT = High-Z)
-
2
mA
I
CC3
CC4
CC5
RAS-Only Refresh Current
Average Power Supply Current
RAS-Only Refresh Mode
60ns
70ns
80ns
60ns
70ns
80ns
-
-
-
-
-
-
110
100
90
mA
2
(RAS Cycling, CAS = VIH, tRC = tRC min)
Extended Data Out Page Mode Current
Average Power Supply Current
Extended Data Out Mode
I
I
I
I
130
120
110
mA 1, 3
(RAS = VIL, CAS, Address Cycling: tHPC = tHPC min)
Standby Current (CMOS)
Power Supply Standby Current
(RAS, CAS= VIH, WE, OE, Address and DIN=VIH or VIL
-
1
mA
,
DOUT=High-Z)
CC6
CAS-before-RAS Refresh Current
(tRC = tRC min)
60ns
70ns
80ns
-
-
-
110
100
90
mA
Standby Current RAS = VIH
CAS = VIL
CC8
-
5
mA
1
DOUT = Enable
I
I(L)
Input Leakage Current
Any Input (0V<=VIN<=7V)
-10
-10
10
10
uA
uA
IO(L)
Output Leakage Current
(DOUT is Disabled, 0V<=VOUT<=7V)
Note: 1. ICC depends on output load condition when the device is selected. ICC(max) is specified at the
output open condition.
2. Address can be changed once or less while RAS = VIL
.
3. Address can be changed once or less while CAS = VIH
.
3