HO-NP/SP33-1000 SERIES  
Application information  
Total primary resistance  
The primary resistance is 0.36 mΩ per conductor at 25 °C.  
In the following table, examples of primary resistance according to the number of primary turns.  
Primary resistance  
Number of  
primary turns  
Primary nominal current  
current rms  
Recommended connections  
I
PN [ A ]  
RP [ mΩ ]  
13  
12  
11  
OUT  
1
2
3
0.12  
0.54  
1.18  
8
4
15  
25  
IN  
IN  
IN  
8
13  
9
12  
10  
11  
OUT  
7.5  
12.5  
8.33  
8
9
10  
11  
13  
12  
OUT  
2.67  
5
8
9
10  
Definition of typical, minimum and maximum values  
Minimum and maximum values for specified limiting and safety conditions have to be understood as such as well as values  
shown in “typical” graphs. On the other hand, measured values are part of a statistical distribution that can be specified by an  
interval with upper and lower limits and a probability for measured values to lie within this interval.  
Unless otherwise stated (e.g. “100 % tested”), the LEM definition for such intervals designated with “min” and “max” is that  
the probability for values of samples to lie in this interval is 99.73 %. For a normal (Gaussian) distribution, this corresponds  
to an interval between -3 sigma and +3 sigma. If “typical” values are not obviously mean or average values, those values are  
defined to delimit intervals with a probability of 68.27 %, corresponding to an interval between -sigma and +sigma for a normal  
distribution.  
Typical, maximal and minimal values are determined during the initial characterization of a product.  
Remark  
Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic  
Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: Products/Product Documentation.  
Page 12/15  
17September2013/Version 2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice  
www.lem.com