Dimensions CT 0.1 .. 0.4-P
(in mm. 1 mm = 0.0394 inch)
30
20
11.0
M GND
M GND -
Vcc+
Vcc
12.6
17.8
17.8
-V c + c
c Vc
5±2
0. 5
0.5±0.3
Ø 11
f 11
ø
30
5±
2
4- 0.7
± 0.3
4- 0.7
2-F 2
2-Ø2
(NC)
± 0.3
I
Ip flux-gate
DC
+Vcc
transformer
AC
M
GND
−Vcc
20.3
2-Ø5
± 0.3
2-F 5
+Vcc
+Vcc
-
Vcc
-Vcc
GND
GND
M
4.3
10. 5
10.5
11
M
R
L
Vout
Mechanical characteristics
± 1 mm
(Unless otherwise specified in the above drawings.)
•
Aperture for primary conductor Ø11 mm
•
Connection of secondary
4 pins 0.7 x 0.7 mm
2
Recommended PCB hole
1.2 mm
•
PCB fixation
2 pins Ø2 mm
Recommended PCB hole
2.2 mm
Safety
•
General tolerance
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Remarks
Caution, risk of electrical shock
•
V
OUT
is positive when
I
P
flows in the direction of the
arrow.
•
This transducer induces into the primary circuit a
square wave of 500Hz. This voltage can induce an AC
current in the primary if the primary impedance is low.
•
Primary impedance
≥10Ω
CT0.1-P CT0.2-P CT0.4-P
V
OUT
by induced current
≤±0.5% ≤±0.4% ≤±0.2%
of
I
PN
•
Temperature of the primary conductor should not
exceed 100°C.
061017/9
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 3/3