Specifications
ispLSI 2064E
Power Consumption
Power consumption in the ispLSI 2064E device depends
on two primary factors: the speed at which the device is
operating and the number of Product Terms used.
Figure 3. Typical Device Power Consumption vs fmax
160
150
140
130
Figure 3 shows the relationship between power and
operating speed.
ispLSI 2064E
I
CC (mA)
120
110
100
90
80
70
1
20
40
60
80
100 120 140 160 180 200
f
max (MHz)
Notes: Configuration of Four 16-bit Counters
Typical Current at 5V, 25° C
ICC can be estimated for the ispLSI 2064E using the following equation:
ICC(mA) = 7 + (# of PTs * 0.75) + (# of nets * Max freq * 0.004)
Where:
# of PTs = Number of Product Terms used in design
# of nets = Number of Signals used in device
Max freq = Highest Clock Frequency to the device (in MHz)
The ICC estimate is based on typical conditions (VCC = 5.0V, room temperature) and an assumption of two GLB loads on
average exists. These values are for estimates only. Since the value of ICC is sensitive to operating conditions and the
program in the device, the actual ICC should be verified.
0127A/2064E
8