Genesys 750W/1500W Specifications  
30-50 40-38 60-25 80-19 100-15 150-10 300-5 600-2.6  
750W  
1500W  
1.0 MODEL  
GEN  
6-200  
6
8-180 12.5-120 20-76  
X
X
X
X
X
1.Rated output voltage(*1)  
V
8
12.5  
20  
30  
40  
60  
80  
100  
150  
300  
600  
2.Rated Output Current(*2)  
3.Rated Output Power  
4.Efficiency at 100/200Vac (*3)  
A
W
%
200  
1200  
77/80  
180  
1440  
78/81  
120  
1500  
81/84 83/86  
76  
1520  
50  
38  
25  
1500  
19  
15  
10  
1500  
84/88  
5
2.6  
1560  
83/87  
1500 1520  
83/86 84/88 84/88 84/88 84/88  
1520 1500  
1500  
83/87  
X
1.0 MODEL  
GEN  
V
A
6-100  
6
100  
600  
8-90  
8
90  
12.5-60 20-38  
30-25 40-19 60-12.5 80-9.5 100-7.5 150-5 300-2.5 600-1.3  
X
X
X
X
1.Rated output voltage (*1)  
2.Rated Output Current (*2)  
3.Rated Output Power  
12.5  
60  
20  
38  
30  
25  
40  
19  
60  
12.5  
750  
80  
9.5  
760  
100  
7.5  
150  
5
300  
2.5  
600  
1.3  
W
720  
750  
760  
750  
760  
750  
750  
750  
780  
1.1 CONSTANT VOLTAGE MODE  
1.Max.line regulation ( 0.01% of Vo+ 2mV )(*4)  
2.Max load regulation ( 0.01% of Vo+2mV )(*5)  
3.Ripple and noise p-p 20MHz  
4.Ripple r.m.s 5Hz~1MHz  
5.Remote sense compensation/line  
6.Temp. coefficient  
7.Up-prog. response time, 0~Vomax  
8.Down-prog response time full-load  
9.Down-prog response time no-load  
10.Transient response time (*8)  
mV  
mV  
mV  
mV  
V
2.6  
2.6  
60  
8
2.8  
2.8  
60  
8
3.3  
3.3  
60  
8
4
4
60  
8
5
5
60  
8
6
6
60  
8
8
8
60  
8
10  
10  
80  
8
12  
12  
80  
8
17  
17  
100  
10  
5
32  
32  
125  
25  
5
62  
62  
300  
60  
5
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
1
1
1
1.5  
2
3
4
5
PPM/°C 100PPM/°C from rated output voltage,following 30 minutes warm up  
mS  
mS  
mS  
80mS , N.L/F.L , resistive load  
10  
500  
150mS , N.L/F.L , resistive load  
50  
700  
80  
1000  
150  
2000  
600  
800  
900  
1100  
1200 1500  
2500  
4000  
Less than 1mSec for models up to and including 100V. 2msec for models above 100V  
1.2 CONSTANT CURRENT MODE  
1.Max.line regulation (0.01% of Io+ 2mA)(*4)  
2.Max.load regulation (0.01% of Io+5mA)(*6)  
3.Ripple r.m.s 5Hz~1MHz . (*7)  
1.Max.line regulation (0.01% of Io+ 2mA)(*4)  
2.Max.load regulation (0.01% of Io+5mA)(*6)  
3.Ripple r.m.s 5Hz~1MHz .(*7)  
mA  
mA  
mA  
mA  
mA  
mA  
12  
15  
200  
2
5
400  
11  
14  
180  
2
5
360  
8
11  
120  
2
5
240  
5.8  
8.8  
76  
2
5
152  
4.5  
7.5  
63  
2
5
125  
3.9  
6.9  
48  
2
5
95  
3.25  
6.25  
38  
2
5
75  
2.95  
5.95  
29  
2
5
57  
2.75  
5.75  
23  
2
5
45  
2.5  
5.5  
18  
2
5
35  
2.25  
5.25  
13  
2
5
25  
2.13  
5.13  
8
2
5
X
X
X
X
X
X
X
12  
4.Temp. coefficient  
PPM/°C 100PPM/°C from rated output voltage,following 30 minutes warm up  
X
1.3 PROTECTIVE FUNCTIONS  
1. OCP  
2. OCP Foldback  
3. OVP type  
4. OVP trip point  
5. Over Temp. Protection  
0~105% Constant Current  
Output shut down when power supply change from CV to CC. User selectable.  
Inverter shut-down, manual reset by AC input recycle or by OUT button  
0.5~7.5V 0.5~10V 1~15V 1~24V 2~36V 2~44V 5~66V 5~88V 5~110V 5~165V 5~330V 5~660V  
User selectable , latched or non latched  
X
X
X
X
X
X
X
X
X
X
1.4 ANALOG PROGRAMMING AND MONITORING  
1.Vout Voltage Programming  
2.Iout Voltage Programming  
3.Vout Resistor Programming  
4.Iout Resistor Programming  
5.On/Off control (rear panel)  
6.Output Current monitor  
7.Output Voltage monitor  
8.Power Supply OK signal  
9. CV/CC indicator  
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-0.5% of rated Vout.  
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-1% of rated Iout.  
0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity:+/-1% of rated Vout.  
0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity:+/-1.5% of rated Iout.  
By electrical. Voltage: 0~0.6V/2~15V,or dry contact ,user selectable logic  
0~5V or 0~10V , accuracy:1% , user selectable  
0~5V or 0~10V ,accuracy:1% ,user selectable  
5V-OK, 0V-Fail 500ohm impedance  
CV: TTL high (4~5V) source: 10mA, CC: TTL low (0~0.4V):10mA  
Dry contact. Open:off , Short: on. Max. voltage at Enable/Disable in: 6V  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
10. Enable/Disable  
1.5 FRONT PANEL  
1.Control functions  
Vout/ Iout manual adjust by separate encoders (coarse and fine adjustment selectable)  
OVP/UVL manual adjust by Volt. Adjust encoder  
AC on/off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control  
Address selection by Voltage (or current) adjust encoder. No of addresses:31  
RS232/485 and IEEE488.2 selection by IEEE enable switch and DIP switch  
Baud rate selection: 1200,2400,4800,9600 and 19,200 bps  
Voltage 4 digits , accuracy: 0.5%+/-1 count  
Current 4 digits, accuracy: 0.5%+/-1 count  
Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
2.Display  
3.Indications  
1.6 Interface RS232&RS485 or Optional GPIB Interface  
750W  
X
1500W  
X
Model  
V
6
8
12.5  
20  
30  
40  
60  
80  
100  
150  
300  
600  
Remote Voltage Programming (16 bit)  
Resolution (0.012% of Vomax)  
Accuracy (0.05%Vomax+0.05% of Vo Actual Output)  
mV  
mV  
0.72  
6.0  
0.96  
8.0  
1.50  
12.5  
2.40  
20  
3.60  
30  
4.80  
40  
7.2  
60  
9.6  
80  
12  
100  
18  
150  
36  
300  
72  
600  
X
X
X
X
Remote Current Programming (16 bit)  
Resolution (0.012% of Iomax)  
Accuracy (0.05% of Iomax+0.05% of Io Actual Output)  
Resolution (0.012% of Iomax)  
mA  
mA  
mA  
mA  
12  
10  
24  
20  
10.8  
9
21.6  
18  
7.2  
6
14.4  
12  
4.56  
3.8  
9.12  
7.6  
3.0  
2.5  
6
2.28  
1.9  
4.56  
3.8  
1.50  
1.25  
3.0  
1.14  
0.95  
2.28  
1.9  
0.90  
0.75  
1.80  
1.50  
0.60  
0.5  
1.20  
1
0.30  
0.25  
0.60  
0.5  
0.16  
0.13  
0.32  
0.26  
X
X
X
X
Accuracy (0.05% of Iomax+0.05% of Io Actual Output)  
5
2.5  
Readback Voltage  
Resolution (0.012% of Vomax)  
Accuracy (0.1%Vomax+0.1% of Vo Actual Output)  
mV  
mV  
0.72  
12  
0.96  
16  
1.50  
25  
2.40  
40  
3.60  
60  
4.80  
80  
7.2  
120  
9.6  
160  
12  
200  
18  
300  
36  
600  
72  
1200  
X
X
X
X
Readback Current  
Resolution (0.012% of Iomax )  
Accuracy (0.1% of Iomax+0.3% of Io Actual Output)  
Resolution (0.012% of Iomax )  
mA  
mA  
mA  
mA  
12  
400  
24  
10.8  
360  
21.6  
720  
7.2  
240  
14.4  
480  
4.56  
152  
9.12  
304  
3.0  
100  
6
2.28  
76  
4.56  
152  
1.50  
50  
3.0  
1.14  
38  
2.28  
76  
0.9  
30  
1.80  
60  
0.60  
20  
1.20  
40  
0.30  
10  
0.60  
20  
0.16  
5.2  
0.32  
10.4  
X
X
X
X
Accuracy (0.1% of Iomax+0.3% of Io Actual Output)  
800  
200  
100  
OVP Programming  
Resolution (0.1% of Vomax)  
Accuracy (1% of Vomax)  
mV  
mV  
6
60  
8
80  
12  
125  
20  
200  
29  
300  
39  
400  
59  
600  
78  
98  
146  
1500  
293  
3000  
586  
6000  
X
X
X
X
800 1000  
*1: Minimum voltage is guaranteed to maximum 0.2% of Vomax. *3: At maximum output power.  
*5: From No-load to Full-load, constant input voltage.  
*2: Minimum current is guaranteed to maximum 0.4% of Iomax. *4: 85~132Vac or 170~265Vac, constant load. *6: For load voltage change, equal to the unit voltage rating, constant input voltage.  
*7: For 6V models the ripple is measured at 2~6V output voltage and full output current. For other models, the ripple is measured at 10~100% output voltage and full output current.  
*8: Time for the output voltage to recover within 0.5% of its rated for a load change 10~90% of rated output , Output set-point:10~100%.  
Accuracy -Values have been calculated at Vomax & Io max  