Crystal Units
Surface Mount Type CX5032SB (CX-96F)
5.0 3.2mm for Mobile Communications, SRWI
×
How to Order
Features
CX5032SB 26000 F0 F L J ZZ
• Reference frequency
for telecommunication systems
• Reflow compatible
• Using ceramic package resulting
in high reliability
①
②
③ ④ ⑤⑥ ⑦
①Code
②Typical Frequencies
Code Freq.(kHz) Code Freq.(kHz)
12000 12000.000 19200 19200.000
12800 12800.000 26000 26000.000
13000 13000.000 32000 32000.000
14400 14400.000 40000 40000.000
16000 16000.000 48000 48000.000
*Please inquire about frequencies other than the above.
③Load Capacitance
• Small and low profile
Applications
• Mobile Communications, Bluetooth,
Wireless LAN
Pb Free
RoHS Compliant
F0
10pF
Specifications
④Frequency Stability
1010-6
Items
Symbol
Specification
Units
Remarks
F
⑤Operating Temperature Range
f_nom 9843.75 to 49999 50 to 120(MHz) kHz
Frequency Range
Overtone Order
Frequency Tolerance
Frequency Temp. Characteristics
Motional Series Resistance
Level of Drive
L
30°C to 85°C
OT Fundamental
f_tol 10
3rd Overtone
––––
⑥Frequency Temperature Stability
10-6 @ 25°C
J
1510-6
⑦Special
f_tem 15
10-6 ref.@ 25°C Over Operating Temp. Range
ZZ
Custom Specification
R1 Table 1
DL Table 2
CL 10
ohm
W
pF
Load Capacitance
Operating Temp. Range
Storage Temp. Range
T_use 30 to 85
T_stg 40 to 85
°C
°C
* Please inqurie about specifications other than the above.
Table1 Motional Series Resistances
Table2 Level of Drive
Frequency Range
Units
Frequency Range
Units
Motional Series Resistance
Level of Drive
10 (100 max.)
10 (100 max.)
9843.75 to 9999kHz
10000 to 11999kHz
12000 to 25999kHz
26000 to 49999kHz
50 to 120(MHz)
150
80
50
40
80
9843.75 to 49999kHz
W
50 to 120(MHz)(3rdO.T)
ohm
Dimensions
Recommended Land Pattern
(Unit : mm)
(Unit : mm)
#4
#3
#2
3.10.1
#1
4-R0.2
4.90.1
0.70.1
CONNECTION
(TOP VIEW)
1.3
#4
GND
#3
#1
#4
#2
HOT
2.45
2.1
7.0
2.45
1.3
0.9
HOT
GND
#1
#2
#3
4.55
Terminals 2 and 4 need to be
connected to the case.
2.3
- 39 -