欢迎访问ic37.com |
会员登录 免费注册
发布采购

KK33197AN-01 参数 Datasheet PDF下载

KK33197AN-01图片预览
型号: KK33197AN-01
PDF下载: 下载PDF文件 查看货源
内容描述: 汽车雨刮洗涤定时器 [Automotive Wash Wiper Timer]
分类和应用:
文件页数/大小: 7 页 / 215 K
品牌: KODENSHI [ KODENSHI KOREA CORP. ]
 浏览型号KK33197AN-01的Datasheet PDF文件第1页浏览型号KK33197AN-01的Datasheet PDF文件第2页浏览型号KK33197AN-01的Datasheet PDF文件第4页浏览型号KK33197AN-01的Datasheet PDF文件第5页浏览型号KK33197AN-01的Datasheet PDF文件第6页浏览型号KK33197AN-01的Datasheet PDF文件第7页  
KK33197A  
Figure 1. Intermittent Wash Wiper Typical Application  
This application shows the KK33197A with the external wirings and two speed  
wiper motor. This application has the Intermittent and Wash Wiper functions.  
INTRODUCTION  
The KK33197A is a wiper timer control device designed for use in harsh automotive applications. The device can perform  
the intermittent, after wash, and continuous wiper timer functions. The KK33197A is designed to directly drive a wiper  
motor relay. The KK33197A is suitable for both front and rear wiper applications. The KK33197A connects directly to the  
vehicle’s battery voltage (Vbat) through a 220resistor used with a 47 µF de–coupling filter capacitor. The device has an  
internal oscillator controlled by one of two external resistors (R2 and R3) in addition to one external capacitor (C2),  
dependent on the application function required. The values of C2 and R2 determine the tb1 time base. Tb1 is used to  
generate the relay wiper activation during the INT function (T3) and the after wash timing (T2) during the wash wipe  
mode. The values C2 and R3 determine the tb2 time base. The tb2 time base is used to generate the pause or intermittent time  
(T4). The intermittent wiper function can generate intermittent timing (T4) from less than 500 ms to more than 30 seconds.  
The intermittent function of the device can be activated by the INT input connected to either ground or Vbat. The  
intermittent timing is externally adjustable by changing the value of resistor R3. The wash wiper timer function detects the  
water pump motor’s operation. When the pump motor activation is detected, the KK33197A turns the wiper on for the entire  
duration of the pump motor’s activation. When the motor is turned off, it generates an after wash timing (T2) to maintain  
the wiping action. The W/W pin is connected to the water pump motor through a protection resistor (R4). The KK33197A  
also has a continuous function, which activates the wiper relay whenever the CONT input is activated. The CONT input is  
connected to a switch through a protection resistor (R5). The CONT input comparator has an input threshold of Vbb/2 with  
hysteresis. The device has internal debounce circuitry, based on the oscillator period. This provides filtering of the  
intermittent (INT) and wash wipe (W/W) input signals (see T1 Debounce Timing paragraph that follows). The device  
directly drives the wiper motor relay. It internally incorporates a 20 V free wheeling zener diode to protect the device  
against overvoltage spikes produced when relay is switched off.  
Intermittent Operation  
Conditions:  
W/W not connected or connected to ground.  
CONT not connected or connected to ground.  
INT connected to Vbb or to ground.  
In this configuration, the circuit will respond to the switching of INT to either Vbb or ground after a time T1  
(see T1 Debounce Timing). If INT is disconnected before the end of T1; no action will be taken. After a time T1, the  
output will be switched on for a duration, T3 = 16 x 4 x tb1 and then switched off for a duration, T4 = 144 x 4 x tb2.  
This sequence will continue to repeat so long as INT is disconnected from Vbb or ground for a time duration greater  
than T1. If INT is disconnected during the time T3; the output will remain on for the remainder of T3. This is illustrated  
in the diagram on Figure 2.  
3