欢迎访问ic37.com |
会员登录 免费注册
发布采购

KK2901 参数 Datasheet PDF下载

KK2901图片预览
型号: KK2901
PDF下载: 下载PDF文件 查看货源
内容描述: 四路单电源比较器 [Quad Single Supply Comparator]
分类和应用: 比较器
文件页数/大小: 5 页 / 286 K
品牌: KODENSHI [ KODENSHI KOREA CORP. ]
 浏览型号KK2901的Datasheet PDF文件第1页浏览型号KK2901的Datasheet PDF文件第3页浏览型号KK2901的Datasheet PDF文件第4页浏览型号KK2901的Datasheet PDF文件第5页  
KK2901
MAXIMUM RATINGS
*
Symbol
V
CC
Parameter
Power Supply Voltages
Single Supply
Split Supplies
V
IDR
V
ICR
I
SC
I
IN
T
J
Tstg
T
L
P
D
Input Differential Voltage Range
Input Common Mode Voltage Range (1)
Output Short Circuit to Ground
Input Current, per pin (2)
Junction Temperature
Plastic Packages
Storage Temperature
Lead Temperature, 1mm from Case for 10 Seconds
Power Dissipation @T
A
=25°C
Plastic Package
Derate above 25°C
150
-65 to +150
260
1.0
8.0
°C
°C
°C
W
mW/°C
36
±18
36
-0.3 to V
CC
Continuous
50
mA
V
V
V
Value
Unit
Maximum Ratings are those values beyond which damage to the device may occur.
Functional operation should be restricted to the Recommended Operating Conditions.
Notes:
1. Split Power Supplies.
2. V
IN
<-0.3V. This input current will only exist when voltage at any of the input leads is driven negative.
*
RECOMMENDED OPERATING CONDITIONS
Symbol
V
CC
T
A
DC Supply Voltage
Operating Temperature, All Package Types
Parameter
Min
±2.5
or
5.0
-40
Max
±15
or
30
+85
Unit
V
°C
This device contains protection circuitry to guard against damage due to high static voltages or electric fields.
However, precautions must be taken to avoid applications of any voltage higher than maximum rated voltages to this
high-impedance circuit. For proper operation, V
IN
and V
OUT
should be constrained to the range GND≤(V
IN
or
V
OUT
)≤V
CC
.
Unused inputs must always be tied to an appropriate logic voltage level (e.g., either GND or V
CC
). Unused
outputs must be left open.