欢迎访问ic37.com |
会员登录 免费注册
发布采购

KK24LC04BD 参数 Datasheet PDF下载

KK24LC04BD图片预览
型号: KK24LC04BD
PDF下载: 下载PDF文件 查看货源
内容描述: [EEPROM, 512X8, Serial, CMOS, PDSO8]
分类和应用: 可编程只读存储器电动程控只读存储器电可擦编程只读存储器光电二极管内存集成电路
文件页数/大小: 10 页 / 260 K
品牌: KODENSHI [ KODENSHI KOREA CORP. ]
 浏览型号KK24LC04BD的Datasheet PDF文件第2页浏览型号KK24LC04BD的Datasheet PDF文件第3页浏览型号KK24LC04BD的Datasheet PDF文件第4页浏览型号KK24LC04BD的Datasheet PDF文件第5页浏览型号KK24LC04BD的Datasheet PDF文件第7页浏览型号KK24LC04BD的Datasheet PDF文件第8页浏览型号KK24LC04BD的Datasheet PDF文件第9页浏览型号KK24LC04BD的Datasheet PDF文件第10页  
KK24LC04B/08B
Figure 5. Control Byte Allocation
WRITE OPERATION
Byte Write
Following the start condition from the master, the device code (4 bits), the block address (3 bits),
and the R/W bit which is a logic low is placed onto the bus by the master transmitter. This indicates
to the addressed slave receiver that a byte with a word address will follow after it has generated an
acknowledge bit during the ninth clock cycle. Therefore the next byte transmitted by the master is
the word address and will be written into the address pointer of the
KK24LC04B/08B.
After
receiving another acknowledge signal from the
KK24LC04B/08B
the master device will transmit the
data word to be written into the addressed memory location. The
KK24LC04B/08B
acknowledges
again and the master generates a stop condition. This initiates the internal write cycle, and during
this time the
KK24LC04B/08B
will not generate acknowledge signals (see Figure 6).
Page Write
The write control byte, word address and the first data byte are transmitted to the
KK24LC04B/08B
in the same way as in a byte write. But instead of generating a stop condition the master transmits
up to sixteen data bytes to the
KK24LC04B/08B
which are temporarily stored in the on-chip page
buffer and will be written into the memory after the master has transmitted a stop condition. After
the receipt of each word, the four lower order address pointer bits are internally incremented by one.
The higher order seven bits of the word address remains constant. If the master should transmit
more than sixteen words prior to generating the stop condition, the address counter will roll over
and the previously received data will be overwritten. As with the byte write operation, once the stop
condition is received an internal write cycle will begin (see Figure 8).
Figure 6. Byte Write
6