3.4. Power handling
Receiver mounted in lifetime test device (open rear/open front)
(pink noise shaped according to diagram below, crest factor 2)
1. Max short term power
Signal: lifetime test signal
(0,5sec. ON / 3sec. OFF)
50mW (RMS)
20mW (RMS)
2. Max continuous power
Signal: lifetime test signal
(500h)
Lifetime Test Signal: pink noise, 6dB crest factor, filtered with 2nd order high pass filter at 400Hz and with
2nd order low pass filter at 10kHz
©2011 Knowles Electronics
Page 12 of 22
Release – Revision: A