 浏览型号2403-260-00057的Datasheet PDF文件第13页浏览型号2403-260-00057的Datasheet PDF文件第14页浏览型号2403-260-00057的Datasheet PDF文件第15页浏览型号2403-260-00057的Datasheet PDF文件第16页浏览型号2403-260-00057的Datasheet PDF文件第17页浏览型号2403-260-00057的Datasheet PDF文件第18页浏览型号2403-260-00057的Datasheet PDF文件第20页浏览型号2403-260-00057的Datasheet PDF文件第21页  
2403 260 00057  
4.5.5.  
Impact Durability Test (Tumble Test) – protected product  
Parameter  
Test Method and  
Conditions  
Conditions /  
Sample size  
Evaluation Standard  
Impact durability (in a  
Tumble Tester)  
Speaker in drop test box  
or representative  
mechanics. Random  
drops on steel base.  
30 units  
Component may have reduced  
performance, but must still  
function properly. The  
allowable sensitivity difference  
shall not be greater than ±3 dB  
from initial sensitivity.  
180 drops, 1m  
DUT power off  
(Ref. IEC60068-2-32  
Ed)  
(SPR a7.1.1)  
4.5.6.  
Resistance to Electrostatic Discharge  
Parameter  
Test Method and  
Conditions  
Conditions /  
Sample size  
Evaluation Standard  
Resistance to ESD  
One pole is grounded and 10 exposures on  
All samples fully operable.  
the ESD pulse is applied  
to the other pole. The  
speaker must be stressed  
first with one polarisation  
and then with the other  
polarisation. DUT must be  
discharged between each  
ESD exposure.  
each polarity / 5  
units  
IEC61000-4-2 Level 4  
(SPR c 2.5.1)  
All acoustical parameters  
according specification with  
tolerances increased by  
50%.  
DUT Power off  
Level 4: contact +/- 8kV,  
air +/- 15kV  
4.5.7.  
Water-resistant  
Parameter  
Test Method and  
Conditions  
Conditions /  
Sample size  
Evaluation Standard  
Water resistant acc.  
IPx7  
The part must be  
immersed in 1m of water  
for 30min in a  
10 units  
No ingress of water through  
the products allowed.  
1m, 30min  
(Ref. EN60529)  
Measurements after samples  
are dry.  
appropriate test adapter.  
All samples fully operable.  
The allowable change in  
sensitivity shall not be greater  
than 3 dB. All other acoustical  
parameters according  
specification with tolerances  
increased by 50 %.  