IECQ-CECC and AEC-Q200 Tests
PERIODIC TESTS CONDUCTED FOR IECQꢁCECC AND AECꢁQ200
Sample acceptance
Test ref
Test
Termination type
Additional requirements
Reference
P
N
C
High temperature
exposure (storage)
Un-powered. 1,000 hours @ T=150ºC.
Measurement at 24 2 hours after test conclusion.
MIL-STD-202
Method 108
P1
All types
12
77
0
C0G/NP0 (1B):
All types X7R (2R1):
Y and H only
1,000 cycles -55ºC to +125ºC
Measurement at 24 2 hours after test conclusion.
JESD22
Method JA-104
P2
P3
Temperature cycling
Moisture resistance
12
12
77
77
0
0
T = 24 hours/cycle. Note: Steps 7a and 7b not required.
Unpowered.
MIL-STD-202
Method 106
All types
All types
Measurement at 24 2 hours after test conclusion.
1,000 hours 85ºC/85ꢀRH. Rated voltage or 50V
whichever is the least and 1.5V.
Measurement at 24 2 hours after test conclusion.
MIL-STD-202
Method 103
P4
Biased humidity
12
77
0
Condition D steady state TA=125ºC at full rated.
Measurement at 24 2 hours after test conclusion.
MIL-STD-202
Method 108
P5
P6
Operational life
All types
All types
12
12
77
5
0
0
Note: Add aqueous wash chemical.
Do not use banned solvents.
MIL-STD-202
Method 215
Resistance to solvents
C0G/NP0 (1B):
All types X7R (2R1):
Y and H only
MIL-STD-202
Method 213
P7
P8
Mechanical shock
Vibration
Figure 1 of Method 213. Condition F
12
12
30
30
0
0
5g’s for 20 minutes, 12 cycles each of 3 orientations.
C0G/NP0 (1B):
All types X7R (2R1):
Y and H only
Note: Use 8" x 5" PCB 0.031" thick 7 secure points on one
long side and 2 secure points at corners of opposite sides.
Parts mounted within 2" from any secure point. Test from
10-2,000Hz.
MIL-STD-202
Method 204
Condition B, no pre-heat of samples:
Single wave solder - Procedure 2
MIL-STD-202
Method 210
P9
Resistance to soldering heat
Thermal shock
All types
3
12
0
0
C0G/NP0 (1B):
All types X7R (2R1):
Y and H only
-55ºC/+125ºC. Number of cycles 300.
Maximum transfer time - 20 seconds,
dwell time - 15 minutes. Air-Air.
MIL-STD-202
Method 107
P10
12
30
BS EN132100
Clause 4.8, 4.12
and 4.13
Adhesion, rapid temp change and
climatic sequence
X7R (2R1):
A, F and J only
5N force applied for 10s, -55ºC/+125ºC for 5 cycles,
damp heat cycles
P11
12
12
27
30
0
0
C0G/NP0 (1B):
All types X7R (2R1):
Y and H only
3mm deflection Class I
2mm deflection Class II
P12
Board flex
AEC-Q200-005
BS EN132100
Clause 4.9
P13
P14
P15
P16
Board flex
Terminal strength
Beam load test
X7R (2R1): A, F and J only
All types
1mm deflection
12
12
12
12
12
30
30
45
0
0
0
0
Force of 1.8kg for 60 seconds
AEC-Q200-006
AEC-Q200-003
All types
-
56 days, 40ºC/93ꢀ RH 15x no volts, 15x 5Vdc,
15x rated voltage or 50V whichever is the least
BS EN132100
Clause 4.14
Damp heat steady state
All types
Test results are available on request.
P = Period in months. N = Sample size. C = Acceptance criteria.