欢迎访问ic37.com |
会员登录 免费注册
发布采购

U4164A-400 参数 Datasheet PDF下载

U4164A-400图片预览
型号: U4164A-400
PDF下载: 下载PDF文件 查看货源
内容描述: [Logic Analyzer Module]
分类和应用:
文件页数/大小: 34 页 / 1843 K
品牌: KEYSIGHT [ Keysight Technologies ]
 浏览型号U4164A-400的Datasheet PDF文件第12页浏览型号U4164A-400的Datasheet PDF文件第13页浏览型号U4164A-400的Datasheet PDF文件第14页浏览型号U4164A-400的Datasheet PDF文件第15页浏览型号U4164A-400的Datasheet PDF文件第17页浏览型号U4164A-400的Datasheet PDF文件第18页浏览型号U4164A-400的Datasheet PDF文件第19页浏览型号U4164A-400的Datasheet PDF文件第20页  
16 | Keysight | U4164A Logic Analyzer Module - Data Sheet  
Operating Modes 1  
State operating  
modes  
Conventional state sampling on both edges Dual sample state sampling on one clock  
Quad sample state sampling on  
one clock edge and using quad  
sample mode to capture rising  
and falling edge samples of both  
read and write DQ (data bits) on  
DDR4 or LPDDR4 (synchronous)  
Option -02G  
of the clock (synchronous)  
edge and using dual sample mode to  
capture rising and falling edge samples  
(synchronous)  
Option  
-02G  
Option  
-01G  
Option  
-700  
350 MHz  
(standard) -02G  
Option Option  
-01G  
Option  
-700  
350 MHz  
(standard)  
Maximum  
acquisition rate  
Number of  
available channels  
in one module  
Number of  
available channels  
in a two module set  
Number of  
2.5 Gb/s 2.5 Gb/s 1.4 Mb/s 700 Mb/s 4 Gb/s 2.8 Gb/s 1.4 Gb/s 700 Mb/s  
4 Gb/s  
34  
136  
272  
408  
136  
272  
408  
136  
272  
408  
136  
272  
408  
68  
68  
68  
68  
136  
204  
136  
204  
136  
204  
136  
204  
68  
102  
available channels  
in a three module  
set  
Timing operating modes  
Conventional or transitional timing  
Full channel  
Half channel  
Quarter channel  
All channels  
Option -02G / -01G  
Maximum acquisition rate  
Number of available channels in one module  
2.5 GHz  
136  
5 GHz  
68  
10 GHz  
34  
12.5 GHz  
136  
Number of available channels in a two module set  
Number of available channels in a three module set  
272  
408  
136  
204  
68  
102  
272  
408  
State modes (synchronous)  
Conventional and transitional timing modes (asynchronous)  
Timing zoom  
Memory depth  
(samples)  
Conventional and dual-sample (all  
state speed options); Quad-sample  
(available with Option 02G only)  
Full channel  
Half channel  
Quarter channel  
(requires Option 01G or 02G)  
All options  
Standard (base) memory 2 M  
2 M  
4 M  
8 M  
16 M  
32 M  
64 M  
128 M  
200 M  
400 M  
4 M  
8 M  
8 M  
16 M  
256 K  
256 K  
256 K  
256 K  
256 K  
256 K  
256 K  
256 K  
256 K  
U4164A-004  
U4164A-008  
U4164A-016  
U4164A-032  
U4164A-064  
U4164A-128  
U4164A-200  
U4164A-400  
4 M  
8 M  
16 M  
32 M  
64 M  
128 M  
200 M  
400 M  
800 M  
32 M  
64 M  
128 M  
200 M  
400 M  
800 M  
1.6 G  
16 M  
32 M  
64 M  
128 M  
200 M  
400 M  
Contact Keysight Technologies for information on additional configurations.  
Note: Memory can be upgraded after purchase. See “Upgrades” in “Ordering Information.”  
1. Defined for general purpose use models. For DDR/LPDDR memory applications, either dual-sample or quad-sample modes are used for read/write  
separation. Quad-sample mode is used to capture rising and falling edge samples of both read and write DDR/LPDDR DQ signals for data rates up to  
4 Gb/s from a single probe point. Dual-sample mode is used to capture read and write data instead of higher data rates. Using dual sample mode instead of  
quad sample mode requires, double probing of DDR/LPDDR data (DQ) to capture data rates over 2.5 Gb/s.  
 复制成功!