14 | Keysight | IntegraVision PA2200 Series Power Analyzers - Data Sheet  
Overview  
Basic accuracy (50/60 Hz)  
0.05% of reading  
Best power accuracy (50/60 Hz)  
Power Channels (Voltage and Current)  
0.1% of reading  
PA2201A: 2 Channels,  
PA2203A: 4 Channels  
Voltage Measurement Bandwidth (-3 dB)  
2.5 MHz (-3 dB)  
Current Measurement Bandwidth (2 A or 50 A Input) 100 kHz (-3 dB)  
Current Measurement Bandwidth (External Input)  
Maximum Voltage  
2.5 MHz (-3 dB)  
1000 Vrms (2000 V peak)  
Direct input:  
Maximum Current  
2 Arms (6 A peak) or 50 Arms (100 A peak)  
10 Vrms (30 V peak)  
External transducer:  
Record Size  
Maximum 1.5 M points on each waveform simultaneously  
Digitizing Speed  
Maximum 5 M samples/second at 16 bits on each waveform simultaneously  
12.1- inch capacitive multi-touch/gesture enabled display  
Display size and type  
Power Channels (Voltage and Current)  
Voltage  
Connector  
Safety Banana Plug  
Maximum Voltage  
Input Impedance  
Ranges  
1000 Vrms, 2000 Vpeak  
2 M || 12.5 pF  
5 V, 10 V, 20 V, 50 V, 100 V, 200 V, 500 V, 1000 V  
Pluggable Terminal Block, Phoenix Contact PN: 1967469  
2 Arms, 6 A peak or 50 Arms, 100 A peak  
2 A input: 60 mΩ + 0.10 µH  
Current  
Directly Connected  
Connector  
Maximum Current  
Input Impedance  
50 A input: 6 mΩ + 0.06 µH  
Ranges  
2 A input: 10 mA, 20 mA, 50 mA, 100 mA, 200 mA, 500 mA,  
1 A, 2 A  
50 A input: 200 mA, 500 mA, 1 A, 2 A, 5 A, 10 A, 20 A, 50 A  
Isolated BNC  
External Transducer  
Connector  
Maximum Input Voltage  
Input Impedance  
Ranges  
10 Vrms, 30 V peak  
100 k|| 100 pF  
50 mV, 100 mV, 200 mV, 500 mV, 1 V, 2 V, 5 V, 10 V  
Crest Factor  
3 at full-scale (Unless in conflict with maximum input ratings)  
Maximum Crest Factor of 30 at 10% of full scale  
Current Input Protection  
Internal current shunt measurement paths are not fused. Current limit protection (fuse or breaker)  
and appropriate wire sizing should be provided by the user. Currents in excess of 140% of the  
rated rms currents may cause permanent damage to the current measurement shunts. An internal  
protection mechanism is provided for the 2A shunt to avoid damage due to mis-wiring, but it  
should not be relied upon in situations where higher than 2 Arms currents are expected.  
Isolation  
Voltage and current terminals are isolated from earth ground to 1000 V CAT II rating. Voltage is  
isolated from current with 1000 V CAT II rating  