General Information (continued)  
EMC: Complies with the essential requirements of the European EMC Directive as well as current editions of the following standards (dates and editions  
are cited in the Declaration of Conformity):  
IEC/EN 61326–1  
CISPR Pub 11 Group 1, class B  
AS/NZS CISPR 11  
ICES/NMB–001  
This ISM device complies with Canadian ICES-001.  
Cet appareil ISM est conforme a la norme NMB-001 du Canada.  
SAFETY: Complies with the essential requirements of the European Low Voltage Directive as well as current editions of the following standards (dates and  
editions are cited in the Declaration of Conformity):  
IEC/EN 61010-1  
Canada: CSA C22.2 No. 61010-1  
USA: UL std no. 61010-1  
To find a current Declaration of Conformity for a specific Keysight product, go to: http://www.keysight.com/go/conformity  
Explosive environment  
This product has been type tested to meet the requirements for operation in explosive environments in  
accordance with MIL-STD-810G, Method 511.5, Procedure I.  
Power supply  
External DC input  
External AC power adapter  
Input  
15 to 19 VDC, 40 watts maximum when battery charging  
Efficiency level IV  
100 to 250 VAC, 50 to 60 Hz, 1.25 to 0.56 A  
15 VDC, 4 A  
Output  
Power consumption  
Battery  
14 watts typical, mode dependent  
Lithium ion  
10.8 V, 4.6 A-h  
Operating time  
3.5 hours (typical), mode dependent  
Charge time  
A fully discharged battery takes about 1.5 hours to recharge to 80%. Four hours to 100%.  
Discharge temperature limits  
Charge temperature limits  
Storage temperature limits  
—10 to 60 ºC, ≤ 85% RH  
0 to 45 ºC, ≤ 85% RH  
—20 to 50 ºC, ≤ 85 % RH  
The battery packs should be stored in an environment with low humidity. Extended exposure to  
temperature above 45 ºC could degrade battery performance and life.  
Test port connectors  
≤ 18 GHz models  
26.5 GHz models  
Type-N (f)  
3.5 mm (m) for FieldFox microwave analyzer, N9918A and FieldFox microwave VNA analyzer, N9928A.  
On FieldFox SA N9938A, you may choose 3.5 mm (m) or Type-N (f). Type-N (f) port connector is not  
available for the 26.5 GHz microwave analyzer, N9918A or 26.5 GHz microwave VNA analyzer, N9928A  
≥ 32 GHz models  
NMD 2.4mm (m), torque .9 Nm or 8 in-lb, use torque wrench N9910X-886  
Display  
6.5” transflective color VGA-LED backlit  
Headphone jack connector  
3.5 mm (1/8 inch) miniature audio jack  
 复制成功!