15 | Keysight | N6841A RF Sensor for Signal Monitoring Networks - Data Sheet
Technical Specifications and Operating Characteristics
Amplitude (continue)
Second Order Intercept SOI
(mixer level = –10 dBm)
Frequency
SOI (IP2), dBm
> 26
20 - 850 MHz
850 - 1450 MHz
1450 - 2400 MHz
2400 - 2800 MHz
> 58
> 39
> 29
Third Order Intercept TOI
(IP3, 0 dB user attenuation, 200 kHz tone
spacing, both in IF, mixer level = –10 dBm)
Frequency
TOI (IP3), dBm
> 7.7
20 - 850 MHz
850 - 2700 MHz
2700 - 2900 MHz
2900 - 5900 MHz
5900 - 6000 MHz
> 8.5
> 5.0
> 6.6
> 5.9
IF/Image/Spurious Rejection
Frequency
IF/Image/Spurious Rejection
20 - 200 MHz
> 48.0
> 52.5
> 53.0
> 48.0
> 53.5
> 48.5
> 51.0
200 - 650 MHz
650 - 2650 MHz
2650 - 2750 MHz
2750 - 3850 MHz
3850 - 3880 MHz
3880 - 6000 MHz
Time and Location
Clock synchronization methods
PTP clock modes
GPS or Precision time protocol (IEEE-1588, 2008 compatible)
Grandmaster/Master/Slave
Time reference accuracy to UTC
With GPS < 20 nanoseconds
With PTP < 40 nanoseconds
Data timestamp resolution
GPS
18 nanoseconds
Receiver
Trimble Resolution-SMTx (built into RF Sensor unit)
Operating modes
GPS horizontal accuracy
GPS altitude accuracy
GPS antenna
Fixed or mobile (Land)
< 9 meters (90%)
< 18 meters (90%)
Remote active (3.3V) antenna with 3 meter cable