内容描述: [Infiniium V-Series Oscilloscopes]
分类和应用:
文件页数/大小: 47 页 / 11644 K
品牌: KEYSIGHT [ Keysight Technologies ]
 浏览型号N5463A-1TP的Datasheet PDF文件第8页浏览型号N5463A-1TP的Datasheet PDF文件第9页浏览型号N5463A-1TP的Datasheet PDF文件第10页浏览型号N5463A-1TP的Datasheet PDF文件第11页浏览型号N5463A-1TP的Datasheet PDF文件第13页浏览型号N5463A-1TP的Datasheet PDF文件第14页浏览型号N5463A-1TP的Datasheet PDF文件第15页浏览型号N5463A-1TP的Datasheet PDF文件第16页  
12 | Keysight | Infiniium V-Series Oscilloscopes - Data Sheet  
Industry’s Leading Hardware Serial Trigger (Continued)  
Industry’s only 12�5 Gb/s hardware serial trigger  
with SSC tracking at oscilloscope channel  
The Infiniium V-Series hardware serial trigger’s speed covers  
most common high-speed serial bus rates starting from  
480 Mb/s up to 12�5 Gb/s, which include USB 2�0, USB 3�1, PCI  
Express Gen 3, HDMI 2�0 and SAS-3 applications� Most of these  
External reference clock input is one of the methods to enable SSC  
applications also support spread spectrum clocking (SSC) where  
the high-speed signal is modulated, and the V-Series’ hardware  
serial trigger is able to track the SSC at the oscilloscope input  
channel or with the use of an external reference clock input� The  
hardware serial trigger will recover and generate a sub-rate clock  
when locked to the signal�  
tracking by the hardware serial trigger�  
Industry’s first PRBS error detector  
The PRBS error detector can trigger and display the bit error of  
the PRBS-7, 15, 23, and 31 signals� It identifies the error when  
the pattern does not match the expected PRBS pattern that has  
been set in the oscilloscope� When the next error happens, the  
oscilloscope will replace the display with the next bit error� This  
allows you to discover if the error is related to the bit pattern,  
which is related to inter-symbol interference (ISI)� The hardware  
serial trigger provides an eye view plot to show the signal quality  
of the signal received�  
PRBS error detector triggers on a bit error in the PRBS-15 signal� An  
eye view plot (bottom left) is provided to show the quality of the signal  
received by the hardware serial trigger� The hardware serial trigger  
works when there is enough eye opening (blue area) to discern the bit  
value�  
Use with InfiniiScan’s software serial trigger for up  
to 240-bit sequence trigger  
The hardware serial trigger can be combined with InfiniiScan’s  
software event trigger to provide a two-stage trigger for up to  
240-bit sequence� This is particularly powerful for the V-Series  
with its deep acquisition memory (up to 2 Gpts), providing long  
trace capture of 25 ms at the high resolution sampling rate of  
80 GSa/s� The hardware first finds the 160-bit event condition  
and then uses InfiniiScan for an additional 80-bit event trigger�  
The InfiniiScan event trigger is not limited to bit sequence search�  
Other search functions such as zone touch trigger allow you to  
visually draw zones on the oscilloscope display as a second stage  
trigger�  
Hardware serial trigger and InfiniiScan’s software serial trigger provide  
up to 240-bit sequence trigger�  
 复制成功!