28 | Keysight | Infiniium V-Series Oscilloscopes - Data Sheet
Infiniium V-Series Ordering Configuration
Get the most out of your oscilloscope investment by choosing options and software for your most common tasks� Configure your
Infiniium V-Series oscilloscope in three easy steps�
1� Choose your oscilloscope, memory and options
Oscilloscope main-frame
Oscilloscope models 1
DSO models(4
analog channels)
DSOV334A
DSOV254A
DSOV204A
DSOV164A
DSOV134A
DSOV084A
Analog bandwidth
Sample rate
2 channel
DSA models(4
analog channels) 2
DSAV334A
DSAV254A
DSAV204A
DSAV164A
DSAV134A
DSAV084A
MS O models(4 analog channels + 16
digital channels)
MSOV334A
MSOV254A
MSOV204A
MSOV164A
MSOV134A
MSOV084A
2 channel
4 channel
4 channel
33 GHz
25 GHz
20 GHz
16 GHz
13 GHz
8 GHz
16 GHz
16 GHz
16 GHz
16 GHz
13 GHz
8 GHz
80 GSa/s
80 GSa/s
80 GSa/s
80 GSa/s
80 GSa/s
80 GSa/s
40 GSa/s
40 GSa/s
40 GSa/s
40 GSa/s
40 GSa/s
40 GSa/s
All models come with front cover, power cord, keyboard, mouse, calibration cable, ESD wrist strap and (5) coax adapters 3�
The 8 and 13 GHz models come standard with two N5442A precision BNC adapters�
Oscilloscope memory depth 4
Acquisition memory depth upgrade
50 Mpts/channel memory
100 Mpts/channel memory 5
200 Mpts/channel memory
500 Mpts/channel memory
1 Gpts/channel memory
Option number on new oscilloscope
Standard
DSOV000-100
DSOV000-200
DSOV000-500
DSOV000-01G
DSOV000-02G
2 Gpts/channel memory
Options
Description
Option number on new oscilloscope
DSOV000-810
Standard on MSO models
DSOV000-801
DSOV000-805
DSOV000-808
N2117A
Hardware serial trigger 6
MSO with additional 16 digital channels 6
1 TB removable solid state drive (SSD) with Windows 7
GPIB card-interface
Performance verification and deskew fixture
Stack mount kit option for stacking two frames
Rack mount kit
N5470A
ANSI Z540 compliant calibration
Calibration + uncertainties + guardbanding (accredited)
DSA option for MSO models 7
DSOV000-A6J
DSOV000-AMG
MSOV000-DSA
1180CZ
Testmobile scope cart
1� DSA models come standard with 100 Mpts/channel, EZJIT Complete, and Serial Data Analysis�
2� Oscilloscope 8, 13, and 16 GHz models come with 3�5 mm female-to-female adapters rated to 25 GHz (part number 1250-3758)� All other models come
with 3�5 mm female-to-female adapters rated to 35 GHz (part number 5061-5311)�
3� Memory depth per channel when 4 channels are turned on�
4� DSA models come with 100 Mpts/channel standard�
5� Either MSO or hardware serial trigger option can be added to the oscilloscope� Upgrade is not available when the oscilloscope already has the MSO or
hardware serial trigger installed�
6� Available for MSO models only� DSA option comes standard with 100 Mpts/channel, EZJIT Complete, and Serial Data Analysis�