17 | Keysight | Infiniium V-Series Oscilloscopes - Data Sheet  
Industry’s Most Comprehensive Software (Continued)  
Open tightly shut eyes with equalization  
Serial data equalization for the Infiniium V-Series provides fast  
and accurate equalization using feed-forward equalization (FFE),  
continuous time linear equalization (CTLE) and decision feedback  
equalization (DFE) modeling in real time� The tool allows you to  
use a combination of the equalization, which is found in actual  
designs�  
Serial data equalization software allows you to input your own  
equalizer settings and tap values that are used in your design,  
allowing you to simulate the eye opening in your receiver� If you  
prefer, the software can find the optimal tap values for you as  
well, which you can use as reference for your designs�  
Serial data equalization opens the closed eye using CTLE and DFE  
methods�  
Powerful and flexible software trigger  
The InfiniiScan software is a powerful tool for identifying signal  
integrity issues that hardware triggering is unable to find in your  
design� This innovative tool scans through thousands of acquired  
waveforms per second to help you isolate signal anomalies,  
saving you time and improving your designs� It includes an 80-bit  
sequence trigger to find events of interest�  
InfiniiScan’s zone touch trigger allows you to draw up to  
eight “must intersect” or “must not intersect” zones on the  
oscilloscope display to visually determine the event-identify  
condition� If you can see the event of interest on the screen,  
the zone touch trigger can be used to quickly and easily  
isolate it, saving significantly more time than complicated  
hardware triggers� Other triggers include non-monotonic edge,  
measurement limit search, runt and pulse width�  
Draw up to eight “must intersect” or “must not intersect” zones to trigger  
on a specific event and condition�  