欢迎访问ic37.com |
会员登录 免费注册
发布采购

N1055A-54M 参数 Datasheet PDF下载

N1055A-54M图片预览
型号: N1055A-54M
PDF下载: 下载PDF文件 查看货源
内容描述: [Wide-Bandwidth Oscilloscope Mainframe and Modules]
分类和应用:
文件页数/大小: 35 页 / 3883 K
品牌: KEYSIGHT [ Keysight Technologies ]
 浏览型号N1055A-54M的Datasheet PDF文件第23页浏览型号N1055A-54M的Datasheet PDF文件第24页浏览型号N1055A-54M的Datasheet PDF文件第25页浏览型号N1055A-54M的Datasheet PDF文件第26页浏览型号N1055A-54M的Datasheet PDF文件第28页浏览型号N1055A-54M的Datasheet PDF文件第29页浏览型号N1055A-54M的Datasheet PDF文件第30页浏览型号N1055A-54M的Datasheet PDF文件第31页  
27 | Keysight | Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - Data Sheet  
Measurements (Continued)  
Configure measurements  
Math measurements - classic DCA user interface  
– Thresholds  
– 10%, 50%, 90% or 20%, 50%, 80% or custom  
– Eye boundaries  
– Define boundaries for eye measurements  
– Define boundaries for alignment  
– Format units for  
– Four user-definable functions operator — Magnify, invert,  
subtract, versus, min, max  
– Source — Channel, function, memory, constant, response  
(TDR)  
Signal processing measurements - FlexDCA  
– Duty cycle distortion — Time or percentage  
– Extinction/Contrast ratio — Ratio, decibel or percentage  
– Eye height — Amplitude or decibel (dB)  
– Eye width — Time or ratio  
– Math — Add, subtract, multiply, average, invert, maximum,  
minimum, median  
– Signal processing — Difference (differentiate), summation  
(integrate), interpolation (linear, Sin(x)/x), filters: 4th order  
bessel, butterworth, gaussian  
– Average power — Watts or decibels (dBm)  
– Top base definition  
– Transforms — FFT, versus  
– Equalizer (Option 201) — Linear feed-forward  
– Equalizer (LFE, up to 64 taps)  
Automatic or custom  
Δ time definition  
– Simulation (Option SIM) — De-embedding, embedding,  
random jitter, random noise  
– First edge number, edge direction, threshold  
– Second edge number, edge direction, threshold  
– Jitter mode  
Calibrate - classic DCA user interface  
– Units (time or unit interval, watts, volts, or unit amplitude)  
– Signal type (data or clock)  
– Measure based on edges (all, rising only, falling only)  
– Graph layout (single, split, quad)  
– All calibrations  
– Module (amplitude)  
– Horizontal (time base)  
– Extinction ratio  
– Probe  
– Optical channel  
Quick measure configuration  
When using the classic DCA interface, “Quick Measure” measure-  
ments are initiated by pressing the <Multi-Purpose> button on  
the front panel.  
– Front panel calibration output level  
– User selectable –2 to 2 V  
– Four user-selectable measurements for each mode, eye-  
mask, TDR, etc.  
– Default settings (Eye/Mask mode) extinction ratio, jitter RMS,  
average power, crossing percentage  
– Default settings (Oscilloscope mode) rise time, fall time,  
period, V amptd  
Utilities  
– Set time and date  
– Remote interface  
– Set GPIB interface  
– Touch screen configuration/calibration  
– Calibration  
– Disable/enable touch screen  
– Upgrade software  
Histograms  
Configure  
– Upgrade mainframe  
– Upgrade module  
– Histogram scale (1 to 8 divisions)  
– Histogram axis (vertical or horizontal)  
– Histogram window (adjustable window via marker knob)  
 复制成功!