欢迎访问ic37.com |
会员登录 免费注册
发布采购

N1045A-04M 参数 Datasheet PDF下载

N1045A-04M图片预览
型号: N1045A-04M
PDF下载: 下载PDF文件 查看货源
内容描述: [Wide-Bandwidth Oscilloscope Mainframe and Modules]
分类和应用:
文件页数/大小: 35 页 / 3883 K
品牌: KEYSIGHT [ Keysight Technologies ]
 浏览型号N1045A-04M的Datasheet PDF文件第25页浏览型号N1045A-04M的Datasheet PDF文件第26页浏览型号N1045A-04M的Datasheet PDF文件第27页浏览型号N1045A-04M的Datasheet PDF文件第28页浏览型号N1045A-04M的Datasheet PDF文件第30页浏览型号N1045A-04M的Datasheet PDF文件第31页浏览型号N1045A-04M的Datasheet PDF文件第32页浏览型号N1045A-04M的Datasheet PDF文件第33页  
29 | Keysight | Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - Data Sheet  
Ordering Information  
Optical/electrical modules  
86100D  
86100D  
Infiniium DCA-X mainframe  
Hardware options  
86105C  
9 GHz optical channel; single-mode and multimode,  
amplified (750 to 1650 nm) 20 GHz electrical channel  
155 Mb/s through 8.5 Gb/s (choose 4 filter rates from  
Options 86105C-110 through 86105C-195)  
155 Mb/s  
622 Mb/s (also covers 614 Mb/s)  
1.063 Gb/s  
1.244/1.250 Gb/s (also covers 1.229 Mb/s)  
2.125 Gb/s  
2.488/2.500 Gb/s (also covers 2.458 Gb/s)  
2.666 Gb/s  
3.125 Gb/s (also covers 3.072 Gb/s)  
4.250 Gb/s  
5.0 Gb/s  
6.250 Gb/s (also covers 6.144 Gb/s)  
8.5, 9.953, 10.3125, 10.519, 10.664, 10.709, 11.096,  
11.317 Gb/s  
86100D-STR  
86100D-ETR  
86100DU-ETR Enhanced trigger upgrade kit  
Standard trigger  
Enhanced trigger  
86105C-100  
86105C-110  
86105C-120  
86105C-130  
86105C-140  
86105C-150  
86105C-160  
86105C-170  
86105C-180  
86105C-190  
86105C-193  
86105C-195  
86105C-200  
86100D-PTB  
Precision timebase integrated in the mainframe  
86100DU-PTB Upgrade mainframe with integrated precision timebase  
86100D-GPI  
86100D-GPN No GPIB card interface  
86100D-090  
86100D-092  
86100D software options  
86100D-xxx Are permanent fixed-node licenses installed by the  
factory  
GPIB card interface installed (default)  
Removable hard drive  
Internal hard drive (default)  
86100DU-xxx Are permanent fixed-node licenses installed by the  
customer (software upgrades)  
Are permanent transportable licenses installed by the  
customer  
86100DT-xxx  
86105C-300  
86105D2  
Combination of rates available in 86105C-100 and  
86105C-200  
20 GHz optical channel; single-mode and multimode,  
(750 to 1650 nm); filters for 8.5, 9.953, 10.3125, 10.519,  
10.664, 10.709, 11.096, 11.317, 14.025 Gb/s; 35 GHz  
electrical channel  
The “-xxx” option code provides the same functionality independent of the  
prefix (i.e., 86100D or 86100DU or 86100DT)  
86100D-BFP  
86100D-061  
86100D-062  
86100D-200  
86100D-201  
86100D-202  
86100D-300  
Automatic fixture removal  
MATLAB - Basic Oscilloscope package  
MATLAB - Standard Oscilloscope package  
Enhanced jitter analysis software  
Advanced waveform analysis software  
Enhanced impedance and S-parameter software  
Amplitude analysis/RIN/Q-factor  
86105D-100  
86105D-200  
Identical capability as 86105D, 14.025 Gb/s filter not  
included  
Identical capability as 86105D, only filter provided is  
14.025 Gb/s  
86105D-IRC 3 System impulse response correction calibration  
86100DU-400 PLL and jitter spectrum software 1  
86100D-401  
86100D-SIM  
86100D-500  
86100D-9FP  
N1012A  
N1014A  
N1019A  
N1081A  
N1082A  
Advanced EYE analysis software 1  
InfiniiSim-DCA software  
Productivity package software  
PAM-N analysis software, fixed perpetual license  
OIF CEI compliance and debug application  
SFF-8431 compliance and debug application  
User-defined application  
IEEE 802.3 KR/KR4 application  
IEEE 802.3bj XLAUI, CAUI-10 and nPPI; IEEE 802.3bm  
86105D-281  
34 GHz optical channel, filters for 15, 25.78 , 27.95,  
28.05 Gb/s (contact Keysight for additional 14.025 Gb/s  
filter) 4. 50 GHz electrical channel  
1. Fixed node customer installed or transportable customer installed  
(86100DU or 86100DT). Not available as a factory-installed license.  
2. This module is not compatible with the 86100A and 86100B DCA  
mainframes. If you want to upgrade older DCAs, contact Keysight  
Technologies to discuss current trade-in deals.  
3. System impulse response correction calibration provides a unique  
calibration file for the optical channel(s). The FlexDCA user interface uses  
this calibration file to create ideal reference receiver responses for more  
accurate and consistent transceiver compliance testing. IRC also allows  
reference receivers to be defined at any data rate within ± 50% of the  
hardware response. This allows optical receivers to significantly extend  
their operating range.  
CAUI-4 (Option -4TP)  
IEEE 802.3 40GBASE-CR4 and 100GBASE-CR10  
IEEE802.3 KR4/CR4 application  
N1083A  
N1084A  
N1085A  
PAM4 Measurement application for Ethernet and OIF-CEI  
4. A 15 Gb/s filter is provided with Option 281 and 282 that closely  
approximates the response required for 16X Fibre Channel compliance  
testing. Contact Keysight for a special option that verifies compliance  
of the 86105D-281 and 86115D-282 to the 16X Fibre Channel reference  
receiver specification.  
IEEE Measurements option 1TP  
OIF-CEI Measurements option 4TP  
Misc options  
86100D-AFP  
86100D-AX4  
86100D-AXE  
86100D-UK6  
Module slot filler panel  
Rack mount flange kit  
Rack mount flange kit with handles  
Commercial cal certificate with test data  
86100DU-WN7 Upgrade to Windows 7 operating system  
Note:  
Option BFP requires Option 202.  
For complete PAM4 analysis capability, Option 9FP requires Options  
200/201/300/401.  
Options 200, 201, and SIM require Option ETR (enhanced trigger).  
Option 300 requires Options 200 and ETR.  
Option 400 requires Microsoft Office Excel 2007/2010.  
 复制成功!