03 | Keysight | InfiniiVision 4000 X-Series Oscilloscopes - Data Sheet
Oscilloscope Experience Redefined:
Experience the Speed, Usability, and Integration (Continued)
Overview of Keysight InfiniiVision X-Series oscilloscopes
InfiniiVision
6000 X-Series
4000 X-Series
3000T X-Series
2000 X-Series
Analog channels
Digital channels
Bandwidth
2 or 4
2 or 4
2 or 4
2 or 4
16 (MSO models or upgrade) 16 (MSO models or upgrade) 16 (MSO models or upgrade) 8 (MSO models or upgrade)
1, 2.5, 4, 6 GHz
200, 350, 500 MHz, 1,
1.5 GHz
100, 200, 350, 500 MHz,
1 GHz
70, 100, 200 MHz
Max sample rate
Max memory depth
20 GSa/s
4 Mpts
5 GSa/s
4 Mpts
5 GSa/s
4 Mpts
2 GSa/s
100 kpts (standard)
1 Mpts (option)
Max waveform update
rate
> 450,000 wfms/sec
> 1,000,000 wfms/sec
> 1,000,000 wfms/sec
> 50,000 wfms/sec
Display
Zone touch trigger
Voice control
12.1-inch, capacitive touch
Standard
Standard
12.1-inch, capacitive touch
Standard
No
8.5-inch, capacitive touch
Standard
No
8.5-inch
No
No
WaveGen 20-MHz
function/arbitrary
waveform generator
Dual-channel AWG (option)
Dual-channel AWG (option)
Single-channel AWG (option) Single-channel function
(option)
Integrated DVM
Option
Option
Option
Option
Integrated hardware
counter
5 digits (standard), 10 digits
+ totalizer (option)
5 digits (standard)
5 digits (standard), 8 digits + 5 digits (standard)
totalizer (option)
Search and navigate
Segment memory
Mask/limit test
Serial protocol analysis
options
Standard, lister supported
Standard
Option
Standard, lister supported
Standard
Option
Standard, lister supported
Standard
Option
Serial only
Option
Option
I2C/SPI, UART/RS232, CAN/ I2C/SPI, UART/RS232, CAN/ I2C/SPI, UART/RS232, CAN/ I2C/SPI, UART, CAN/LIN (will
CAN-dbc/CAN-FD/LIN/LIN
CAN-dbc/CAN-FD/LIN/LIN
CAN-dbc/CAN-FD/LIN/LIN
symbolic, SENT, FlexRay,
I2S, MIL-STD1553, CXPI,
ARINC429
not operate simultaneously
with digital channels)
symbolic, SENT, FlexRay, I2S, symbolic, SENT, FlexRay,
MIL-STD1553, ARINC429,
USB 2.0
I2S, MIL-STD1553, CXPI,
ARINC429, USB 2.0
Advanced analysis
options
Power analysis, USB 2.0
signal quality test, HDTV
analysis, FPGA
Power analysis, USB 2.0
signal quality test, HDTV
analysis, FPGA
Power analysis, HDTV
analysis
No
Color grade
Histogram
Standard
Standard
No
No
No
No
No
No
FFT
Standard enhanced FFT
Gated FFT
Standard enhanced FFT
Gated FFT
No
Standard enhanced FFT
Gated FFT
No
Standard
No
No
Multi-domain analysis
Jitter analysis with clock Option
recovery
Realtime eye diagram
Advanced math
Option
Standard, display four
functions simultaneously
No
No
No
No
Standard, display one
function
Standard, display one
function
Connectivity
Standard USB 2.0, LAN,
video (GPIB option), USB
Standard USB 2.0, LAN,
video (GPIB option), USB
Standard USB 2.0 (LAN/
video/GPIB option), USB
Standard USB 2.0 (LAN/
video/GPIB option), USB
mouse and keyboard support mouse and keyboard support mouse and keyboard support keyboard support
Need more bandwidth, sampling rate, and analysis?
Consider the Infiniium 6000 X-Series
– 1, 2.5, 4, and 6 GHz
– 20 GSa/s
– Ultra-low noise at 1 mV/div
– 12.1-inch multi-touch capacitive display with gesture support
– Standard color grade, histogram, and enhanced FFT
– Optional jitter and real-time eye diagram analysis
See www.keysight.com/find/6000X-Series for more details.