Configuration and Ordering Information
Software Platform
Ordering Information
The family of OXI modules—M9403A, M9404A, M9405A,
M9406A, M9407A, and M9408—require no software for
operation. The PXIe chassis provides module power. Once
installed, they simply work. They can be used with and
alongside other PXI modules such as an input attenuator
for signal conditioning or paired with a signal source for
transmission or signal analyzer for analysis.
Model
Description
M9403A¹
PXIe Optical Transmitter:
300 kHz to 26.5 or 50 GHz
M9403A-H01
M9403A-H02
M9403A-F26
M9403A-F50
M9403A-CA3
O/E Converter
O/E Converter with Amplifier
Frequency 300 kHz to 26.5 GHz
Frequency 300 kHz to 50 GHz
Optical Cable 3 Meter E2000pc to
E2000PC
Additional Information
M9404A¹
PXIe Optical Receiver:
300 kHz to 26.5 or 50 GHz
Chassis slot compatibility: PXI system slot
M9404A-H01
M9404A-H02
M9404A-F26
M9404A-F50
M9404A-CA3
O/E Converter
O/E Converter with Amplifier
Frequency 300 kHz to 26.5 GHz
Frequency 300 kHz to 50 GHz
Accessories
Model
Description
Optical Cable 3 Meter E2000pc to
E2000PC
M9018A
PXI 18-slot chassis
M9405A
PXIe Amplifier:
300 kHz to 26.5 or 50 GHz
M9405A-H01
PXIe Amplifier: 300 kHz to 26.5 or
50 GHz
M9404A-F26
M9404A-F50
M9406A¹
Frequency 300 kHz to 26.5 GHz
Frequency 300 kHz to 50 GHz
PXIe Optical to USB 2.0
M9404A-H01
M9404A-CA3
M9407A¹
PXIe Optical to USB 2.0
Optical cable 3 meter
Figure 6. M9018A 18-slot chassis.
PXIe Optical to 4 port USB 2.0 Hub
PXIe Optical to 4 port USB 2.0 Hub
Optical cable 3 meter LC to LC
RF Reflectometer: 10 MHz to 50 GHz
M9404A-H01
M9404A-CA3
M9408A
1. Need customer furnished single-mode optical fiber.
Definitions for specifications
Specifications describe the warranted performance of calibrated instruments that have been stored for a minimum of
2 hours within the operating temperature range of 0 to 55 °C, unless otherwise stated, and after a 45 minute warm-up period. Data represented
in this document are specifications unless otherwise noted.
Characteristics describe product performance that is useful in the application of the product. Characteristics are often referred to as Typical or
Nominal values.
– Typical describes characteristic performance, which 80% of instruments will meet when operated over a 20 to 30 °C temperature range.
Typical performance is not warranted.
– Nominal describes representative performance that is useful in the application of the product when operated over a 20 to 30°C temperature
range. Nominal performance is not warranted.
Note: All graphs contain measured data from several units at room temperature unless otherwise noted.
11