15 | Keysight | M9485A PXIe Multiport Vector Network Analyzer 1 MHz/50 MHz to 9 GHz - Data Sheet
Test port output (source)
Test port output frequency
Description
Typical
Frequency range
Resolution
50 MHz to 9 GHz
1 Hz
Accuracy
See M9300A
Test port output power
Description
Typical
Nominal power (preset power)
0 dBm
Power range/Power sweep range
(Source: Standard Configuration)
50 M to 6 GHz
–90 dBm to max leveled power
–30 dBm to max leveled power
6 G to 9 GHz
Max leveled power
(Source: Standard Configuration)
10 M to 50 MHz
50 M to 3 GHz
3 G to 5 GHz
5 G to 7 GHz
-6 dBm
17 dBm
16 dBm
13 dBm
12 dBm
7 G to 9 GHz
Resolution
0.01 dB
Level accuracy1
(Source: Standard Configuration)
Normal measurement
Leveling mode: Internal
50 M to 6 GHz, 0 dBm
6 G to 9 GHz, 0 dBm
± 0.5 dB
± 1.0 dB
Leveling mode: Open loop
50 M to 6 GHz, 0 dBmm
6 G to 9 GHz, 0 dBm
± 1.0 dB
±1.75 dB
Level linearity2
(Source: Standard Configuration)
Leveling mode: Internal
–20 dBm to max leveled power, 50 M to 6 GHz
–20 dBm to max leveled power, 6 G to 9 GHz
–85 dBm to –20 dBm, 50 M to 3 GHz
–85 dBm to –20 dBm, 3 G to 6 GHz
–30 dBm to –20 dBm, 6 G to 9 GHz
Leveling mode: Open loop
± 0.5 dB
± 1.0 dB
± 1.4 dB
± 1.5 dB
± 2.3 dB
–20 dBm to max leveled power, 50 M to 6 GHz
–20 dBm to max leveled power, 6 G to 9 GHz
–85 dBm to –20 dBm, 50 M to 3 GHz
–85 dBm to –20 dBm, 3 G to 6 GHz
–30 dBm to –20 dBm, 6 G to 9 GHz
± 0.5 dB
± 1.0 dB
± 2.7 dB
± 2.8 dB
± 3.6 dB
1. System Power calibration is required.
2. Level linearity given is relative to 0 dBm