09 | Keysight | M9203A PXIe High-Speed Digitizer/Wideband Digital Receiver - Data Sheet
Technical Specifications and Characteristics (continued)
Digital conversion
Resolution
12 bits
Acquisition memory
-M02
-M10
-M40
256 MB (64 MSamples/ch)
1 GB (256 MSamples/ch)
4 GB (1 GSamples/ch)
Sample clock sources
Internal clock source
Internal or external
Internal, external reference
Real-time sampling rates
-SR2
-SR2, -INT
1.6 GS/s
3.2 GS/s
Sampling jitter
225 fs (nominal)1
Clock accuracy
±15 ppm (nominal)
External clock source (CLK IN MMCX connector)
Impedance
50 Ω (nominal)
Frequency range2
-SR2
1.8 GHz to 3.2 GHz
Signal level
+5 dBm to +15 dBm (nominal), 0 V DC
Coupling
AC
External reference clock (REF IN SMB connector)
Impedance
50 Ω (nominal)
Frequency range
100 MHz ±1 kHz (nominal)
–3 dBm to +3 dBm (nominal)
AC
Signal level
Coupling
Acquisition modes (depends on firmware options)
Single shot, sequence3, continuous
1. Jitter figure based on phase noise integration from 100 Hz to 1600 MHz.
2. The sampling rate corresponds to half of the external clock frequency in 2-channel mode (non interleaved channels). In interleaved mode (only available
with the INT option), the sampling rate corresponds to the frequency of the external clock signal.
3. Up to 131072 records. Record maximum length = memory size/number of channels.