20 | Keysight | 89601B/BN-200 Basic Vector Signal Analysis, 89601B/BN-300 Hardware Connectivity, 89600 VSA Software - Technical Overview
Hardware connectivity (Option 300)
For a complete list of specifications refer to the measurement platform literature.
Supported hardware
For a complete list of currently supported hardware, go to www.keysight.com/find/89600_hardware
Description
Models
supported
Input
channels
Baseband MIMO
(I/Q)
Analysis
Bandwidth1
Frequency
Range1
EVM
Performance1, 2
Applications
X-Series signal N9000A, N9010A,
1, 2 if
Yes,
optional
2x2 MIMO
Up to 160 MHz; Up to 50 GHz
25 MHz max for
slaved units
0.50% rms -
1.5% rms3
Low cost to high
performance
baseband, RF,
2-ch MIMO
analyzers
N9020A, N9030A
N9010 or
N9020 slaved
together4
with dual
N9010 or
N9020A
analyzers, time
synchronous
only4
N9040B
N9038A
Up to 510 MHz
TBD
MXE EMI
receiver
1 RF
No
No
10 MHz Stan-
dard, 25 MHz
with Option B25 26.5 GHz
(Option 526)
8.4 GHz
(Option 508),
Not Available
CISPR compli-
ance testing,
multiple mea-
surement ap-
plications (like
phase noise)
44 GHz
(Option 544)
PSA spectrum E4440A, E4443A,
1, 2 if
2 units slaved
together
No
No
2x2
No
Up to 80 MHz;
8 MHz max for
slaved units
Up to 50 GHz
0.50% rms -
1.5% rms5
High
performance RF
analyzer
E4445A, E4446A,
E4447A, E4448A
ESA spectrum ESA-E Series
analyzer
1
10 MHz
Up to 26.5 GHz
0.40% rms -
1.8% rms6
Economy RF
analysis
Infiniium
8064, 8104,
1, 2, 3, 4
Yes,
including
dual I+jQ
Up to 4x4,
including
baseband
61 GHz
61 GHz
Not available
Wide band-
oscilloscopes 9064, 91047,
9254, 9404,
(62.5 GHz with
reduced alias
protection)
(62.5 GHz with
reduced alias
protection)
width; base-
band; economic
MIMO analysis
80204, 80304,
80404, 80604,
80804, 81004,
81204, 81304,
90254, 90404,
90604, 90804,
91204, 91304,
X91304, X91604,
X92004, X92504,
X92804, X93204,
X92004Q,X92504Q,
X93304, X95004Q,
X96204Q, 9024H,
9054H, 9104H,
9204H, S054A,
S104A, S204A,
S254A, S404A,
S604A, S804A
Z204A, Z254A,
Z334A, Z504A,
Z634A
1. Depending on model/option.
2. On QPSK signal; full scale signal, fully contained in the measurement span; random data sequence; start frequency ≥15 % of span; alpha/BT ≥0.3; symbol
rate ≥ 1 kHz; averaging = 10; Requires Option AYA. Data provided for comparison purposes only.
3. Frequency <3.6 Ghz; range ≥-30 dBm.
4. Option B40 is not supported (i.e. if any analyzer has Option B40, it cannot be used together with another analyzer).
5. Frequency <3 GHz; range ≥-24 dBm.
6. Frequency between 30 MHz and 3 GHz; range ≥-20 dBm.
7. Full sample rate = 10 Gsa/s.