32 | Keysight | Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - Data Sheet  
Ordering Information (Continued)  
40 to 65 GHz optical/80 GHz electrical sampling module,  
1300 to 1620 nm  
Select exactly one reference receiver option:  
External clock recovery solutions 4  
N1076A electrical clock recovery  
86116C 1  
N1076A-216  
N1076A-232  
N1076A-JSA  
Clock recovery range: 50 MBd to 16 GBd  
Clock recovery range: 50 MBd to 16 GBd  
Jitter spectrum analysis  
86116C-025  
40 GHz optical/80 GHz electrical channels,  
17.0/25.8/27.7 Gb/s reference receiver  
65 GHz optical/80 GHz electrical channels,  
39.81/41.25/43.02 Gb/s reference receiver  
86116C-041  
N1077A optical/electrical clock recovery  
N1077A-216  
N1077A-232  
N1077A-SMS  
N1077A-SXT  
N1077A-JSA  
Clock recovery range: 50 MBd to 16 GBd  
Dual/Quad electrical channel modules  
Clock recovery range: 50 MBd to 16 GBd  
Internal SM and MM splitters  
No splitter (supplied by user)  
Jitter spectrum analysis  
86112A  
Dual 20 GHz electrical channels  
86112A-HBW Dual 30 GHz electrical channels  
86117A  
Dual 50 GHz electrical channels  
Precision waveform analyzer module 1, 3  
Dual electrical channel module with integrated clock recovery and  
precision timebase.  
86118A  
Dual 70 GHz electrical remote sampling channels  
Differential de-skew  
2/4 port 60 GHz electrical remote head  
2 channel remote head, 1.85 mm, female  
86118A-H01  
N1045A 2  
N1045A-02F  
86108A-100  
Dual 32 GHz electrical channels, integrated clock  
recovery (50 Mb/s to 14.2 Gb/s) with integrated  
precision timebase  
N1045A-02M 2 channel remote head, 1.85 mm, male  
N1045A-04F 4 channel remote head, 1.85 mm, female  
86108A-001  
86108A-002  
86108A-400  
86108B options  
86108B-LBW Dual 35 GHz electrical channels  
86108B-HBW Dual 50 GHz electrical channels  
86108B-216  
86108B-232  
86108B-300  
86108B-400  
86108B-PTB  
86108B-JSA  
Two 3.5 mm phase trimmers for skew adjustment  
Two precision 3.5 mm 18 inch cables  
Auxiliary clock recovery Input  
N1045A-04M 4 channel remote head, 1.85 mm, male  
TDR/TDT modules  
54754A 1, 5  
Differential TDR module with dual 18 GHz TDR/electrical  
channels  
N1055A 1, 2  
35/50 GHz, 2/4 port, TDR/TDT remote head  
Fast sampling, mandatory option  
35 GHz, 2 channel remote head, 2.92 mm, female  
35 GHz, 2 channel remote head, 2.92 mm, male  
35 GHz, 4 channel remote head, 2.92 mm, female  
N1055A-FS1  
N1055A-32F  
N1055A-32M  
N1055A-34F  
Clock recovery 50 Mb/s to 16 Gb/s  
Clock recovery 50 Mb/s to 32 Gb/s  
Adjustable loop bandwidth/peaking  
Auxiliary clock recovery input  
Integrated precision timebase  
Jitter spectrum analysis and software clock recovery  
emulation  
N1055A-34M 35 GHz, 4 channel remote head, 2.92 mm, male  
N1055A-52F  
N1055A-52M  
N1055A-54F  
50 GHz, 2 channel remote head, 1.85 mm, female  
50 GHz, 2 channel remote head, 1.85 mm, male  
50 GHz, 4 channel remote head, 1.85 mm, female  
86108B-A23  
86108B-CA2  
86108B-CA3  
86108B-DC2  
86108B-DC3  
86108B-PT2  
Two adapters, 2.4 mm (f) to 3.5 mm (f)  
Matched cable pair, 2.4 to 2.4 mm, 24 inch  
Matched cable pair, 3.5 to 3.5 mm, 18 inch  
Two DC blocks, 2.4 mm, 16 V, 50 kHz to 50 GHz  
Two DC blocks, 3.5 mm, 16 V, 50 kHz to 26.5 GHz  
Two 2.4 mm phase trimmers for ext. skew adjustment  
Phase trimmers  
N1055A-54M 50 GHz, 4 channel remote head, 1.85 mm, male  
N1055A-FS1 Fast sampling  
Precision timebase module  
86107A  
Precision timebase reference module  
86107A-010  
86107A-020  
86107A-040  
2.5 and 10 GHz clock input capability  
10 and 20 GHz clock input capability  
10, 20 and 40 GHz clock input capability  
Clock recovery modules 1  
Nominal impedance  
Frequency range  
The following modules provide a recovered clock from the data signal  
for triggering at indicated data rates:  
Insertion loss (at f max)  
Time delay  
Connectors  
83496B  
50 Mb/s to 7.1 Gb/s Clock recovery module. This module  
is not compatible with the 86100A and 86100B DCA  
mainframes. If you want to upgrade older DCAs, contact  
Keysight Technologies and ask for current trade-in deals.  
Single-ended and differential electrical with integrated  
signal taps  
Single mode (1260 to 1360 nm and 1490 to 1600 nm) and  
multimode (830 to 860 nm and 1260 to 1360 nm) optical.  
Integrated signal taps. Single-ended or differential  
electrical inputs (no signal taps)  
86108B-PT3  
Two 3.5 mm phase trimmers for ext. skew adjustment  
Phase trimmers  
Nominal impedance  
83496B-100  
83496B-101  
Frequency range  
Insertion loss (at f max)  
Time delay  
Connectors  
1. 86100D-ETR is recommended when;  
a. More than 1 TDR module is connected to the same DUT.  
b. Using a DCA module equipped with a rear-panel trigger circuit.  
Examples include 54754A, 83496x, and 86108A/B modules. If  
operating these modules in an 86100D with Option STR, an external  
cable (such as P/N 5062-6690) must be connected from the module’s  
front panel trigger/clock output to the 86100D’s trigger input.  
2. Requires 86100D mainframe (not compatible with 86100A/B/C).  
3. This module is not compatible with the 86100A and 86100B DCA  
mainframes. If you want to upgrade older DCAs, contact Keysight  
Technologies to discuss current trade-in deals.  
83496B-200  
Increase operating range to 50 Mb/s to 14.2 Gb/s  
83496BU-200 Data rate 0.05 to 14.2 Gb/s upgrade  
83496B-201 Shift operating range to 7.1 to 14.2 Gb/s  
83496BU-201 Shift operating range to 7.1 to 14.2 Gb/s upgrade  
83496B-300 Add tunable loop bandwidth “golden PLLcapability  
83496BU-300 Adjustable loop bandwidth upgrade  
4. Supports both DCA-X and DCA-M platforms. For detailed N1076A/  
N1077A specifications, refer to the data sheet located at  
www.keysight.com/find/N1077A. Standalone clock recovery instruments  
are controlled via a USB connection to an 86100D DCA-X mainframe or a  
user-supplied PC running N1010A FlexDCA software.  
5. Included with each of these TDR modules is a TDR trigger cable, two 50 Ω  
SMA terminations and one SMA short.  
 复制成功!