03 | Keysꢀght | 66000A 1200 W DC Modular Power System, GPIB - Data Sheet
Specꢀicatꢀons
Specifications
66101A
(at 0 ° to 55 °C unless otherwise specified)
66102A
66103A
66104A
66105A
66106A
Output ratings at 40°C
Output voltage
Output current
Maximum power
0 to 8 V
0 to 16 A
128 W
0 to 20 V
0 to 7.5 A
150 W
0 to 35 V
0 to 4.5 A
150 W
0 to 60 V
0 to 2.5 A
150 W
0 to 120 V
0 to 1.25 A
150 W
0 to 200 V
0 to 0.75 A
150 W
Programming accuracy (at 25 °C 5 °C)
Voltage
Current
0.03% +
0.03% +
3 mV
6 mA
8 mV
3 mA
13 mV
12 mA
27 mV
54 mV
90 mV
1.2 mA
0.6 mA
0.4 mA
Readback accuracy (via GPIB or keyboard dis-
play at 25 °C 5 °C)
Voltage
Current
0.02% +
0.02% +
2 mV
6 mA
5 mV
3 mA
8 mV
2 mA
16 mV
1 mA
32 mV
54 mV
0.6 mA
0.3 mA
Ripple and noise from 20 Hz to 20 MHz
Constant voltage
rms
2 mV
5 mV
8 mA
3 mV
7 mV
4 mA
5 mV
10 mV
2 mA
9 mV
15 mV
1 mA
18 mV
25 mV
1 mA
30 mV
50 mV
1 mA
peak-to-peak
rms
Constant current
Line regulation
Voltage
0.5 mV
0.5 mV
0.5 mA
1 mV
2 mV
3 mV
5 mV
Current
0.75 mA
0.2 mA
0.1 mA
50 µA
30 µA
Load regulation
Voltage
1 mV
1 mV
1 mV
2 mV
4 mV
7 mV
Current
0.5 mA
0.2 mA
0.2 mA
0.1 mA
50 µA
30 µA
Transient response time
Less than 1 ms for the output voltage to recover within 100 mV of its previous level following any
step change in load current up to 10 percent of the power module rated output current
Supplemental Characteristics
66101A
66102A
66103A
66104A
66105A
66106A
(Non-warranted characteristics determined
by design and useful in applying the product)
Average programming resolution
Voltage
2.4 mV
4.6 mA
50 mV
250 mV
5.9 mV
2.3 mA
120 mV
500 mV
10.4 mV
1.4 mA
200 mV
800 mV
18.0 mV
0.75 mA
375 mV
1 V
36.0 mV
0.39 mA
750 mV
1.5 V
60.0 mV
0.23 mA
1.25 mV
2.5 V
Current
Over voltage protection(OVP)
OVP accuracy