09 | Keysight | 16860A Series Portable Logic Analyzers - Data Sheet
16860A Series Logic Analyzer Specifications and Characteristics (Continued)
Timing (asynchronous) sampling mode
Feature
Full channel
2.5 GHz
400 ps to 10 ns
Up to 128 M
Half channel
5.0 GHz
200 ps
Quarter channel (Optional on 16862A or 16864A, requires options -700 and –T10
10 GHz
100 ps
Up to 512 M
Max sample rate
Sample period
Memory depth
Up to 256 M
Timing mode functional characteristics
Minimum data pulse width
Timing interval accuracy
– Within a 16 channel pod
– Across 16 channel pods
Maximum trigger sequencer speed
Maximum trigger sequence steps
Trigger sequence step branching
Trigger position
1 sample period + 200 ps
± (1 sample period + 130 ps + 0.01% of time interval reading) 1
± (1 sample period + 400 ps + 0.01% of time interval reading) 1
2.5 GHz
8
Arbitrary 4-way if/then/else
Start, center, end or user-defined
Trigger resources
16 patterns evaluated as =, !=, >, >=, <, <=
8 double-bounded ranges evaluated as in range, not in range
4 edge detectors in timing, 3 in transitional timing
1 occurrence counter per sequence level
1 timer
4 flags
1 arm in
Burst trigger
2 event counters
Arbitrary Boolean combinations
Go to
Trigger resource conditions
Trigger actions
Trigger and fill memory
Trigger and go to
Trigger, send e-mail and fill memory
Occurrence counter reset
Set
Flag actions
Clear
Pulse set
Pulse clear
Maximum occurrence counter
Maximum range width
Maximum pattern width
Timer range
999,999,999
64 bits
128 bits single label
200 sample clock period to 27 hours
5 ns
Timer resolution
Timer accuracy
Timer reset latency
± (8 sample clock period + 2 ns + 0.01%)
80 sample clock period
Timing zoom (Captured simultaneously with timing or state sampling mode capture)
Timing analysis sample rate
Timing interval accuracy
– Within a 16 channel block
– Between 16 channel blocks
Memory depth
12.5 GHz (80 ps sample resolution)
± (80 ps + 130 ps + 0.01% of time interval reading)
± (80 ps + 400 ps + 0.01% of time interval reading)
256 K samples
Trigger position
Minimum data pulse width
Start, center, end or user-defined
1 sample period + 200 ps
1. With single-ended flying lead and Soft Touch Pro probes.