MBR1060, MBR1080, MBR1090, MBR10100
MBR
Rating
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
Average Rectified Forward Current (Rated V
R
) T
C
= 133°C
Peak Repetitive Forward Current
(Rated V
R
, Square Wave, 20 kHz) T
C
= 133°C
Nonrepetitive Peak Surge Current
(Surge applied at rated load conditions halfwave, single phase, 60 Hz)
Peak Repetitive Reverse Surge Current (2.0
ms,
1.0 kHz)
Operating Junction Temperature (Note 1)
Storage Temperature
Voltage Rate of Change (Rated V
R
)
Symbol
V
RRM
V
RWM
V
R
I
F(AV)
I
FRM
I
FSM
I
RRM
T
J
T
stg
dv/dt
1060
60
1080
80
1090
90
10100
100
Unit
V
10
20
150
0.5
*65
to +175
*65
to +175
10,000
A
A
A
A
°C
°C
V/ms
Maximum ratings are those values beyond which device damage can occur. Maximum ratings applied to the device are individual stress limit
values (not normal operating conditions) and are not valid simultaneously. If these limits are exceeded, device functional operation is not implied,
damage may occur and reliability may be affected.
1. The heat generated must be less than the thermal conductivity from Junction−to−Ambient: dP
D
/dT
J
< 1/R
qJA
.
THERMAL CHARACTERISTICS
Maximum Thermal Resistance, Junction−to−Case
Maximum Thermal Resistance, Junction−to−Ambient
R
qJC
R
qJA
2.0
60
°C/W
°C/W
ELECTRICAL CHARACTERISTICS
Maximum Instantaneous Forward Voltage (Note 2)
(i
F
= 10 Amps, T
C
= 125°C)
(i
F
= 10 Amps, T
C
= 25°C)
(i
F
= 20 Amps, T
C
= 125°C)
(i
F
= 20 Amps, T
C
= 25°C)
Maximum Instantaneous Reverse Current (Note 2)
(Rated dc Voltage, T
C
= 125°C)
(Rated dc Voltage, T
C
= 25°C)
2. Pulse Test: Pulse Width = 300
ms,
Duty Cycle
≤
2.0%.
v
F
0.7
0.8
0.85
0.95
i
R
6.0
0.10
mA
V
www.kersemi.com
2