RC Snubber Network Metallized Polypropylene
F43 RC Snubber, 160VAC/250VDC, 220VAC/630VDC
and Class X2, 275VAC
Construction
Metallized polypropylene film encapsulated with self-extinguishing
resin in a box of material meeting the requirements of UL 94 V–0.
Benefits
• Approvals (for 275VAC only): ENEC, UL
• Rated voltage: 160VAC/250VDC, 220VAC/630VDC and Class
X2, 275VAC
• Capacitance range: 0.01µF–1.0µF
• Pitch: 15.0mm–27.5mm
• Capacitance tolerance: ± 20%, ± 10%
• Climatic category: 55/100/56, IEC 60068-1 and 40/100/56
(275VAC), IEC 60068-1
• Tape and reel packaging in accordance with IEC 60286-2
• RoHS compliance and lead-free terminations
• Operating temperature range: -55˚C to +100˚C and -40˚C to
+100˚C (275VAC)
Applications
For worldwide use in contact protection, contact interference
suppression and transient suppression.
Ordering Information
F43
Series
RC Snubber,
Metallized
Polypropylene
K
Rated Voltage
I = 250VDC
M = 400VDC
P = 630VDC
K = 275VAC
N
Pitch
I = 15.0
N = 22.5
R = 27.5
3100
Capacitance Code (pF)
Digits 2-4 indicate the first three
digits of the capacitance value.
First digit indicates the number of
zeros to be added.
ZX
Internal Use
progressive Digits
Z_, includes
R Value, Box
Dimensions and
Terminal Version
01
Internal Use
M
Capacitance
Tolerance
J = ±5%
K = ±10%
M = ±20%