Input Voltage = 8.5—19 Vdc
Output voltage = 13.6—13.9 Volt
Output current = 1.0 A max
Operating Temperature Range = -40º—70º C
AA-1113-1
The AA-1113-1 battery charger is designed to
provide charging capability for lead acid batteries
used as backup batteries for vehicular electronic
systems.
The ideal charging voltage of 13.6—13.9 volts will
maintain the battery in excellent operating condi-
tion and help extend the life of the battery to its’
maximum operating life.
The charger will maintain the 13.75 volt output
over the input voltage range of 8.5—19 volts. This
is especially helpful in fleets where vehicle alter-
nator voltage levels may vary due to age and us-
age.
Although it is not shown here this unit is also
available with AWG #18 wire leads instead of the
0.25 “quick-connect terminals”.
Storage temperature range = -40º—100º C
Metal case
Reverse polarity protected
Designed to meet the vibration and shock
requirements of
Mil-Std-810
SAE J1455