型号: CD261XQX
PDF下载: 下载PDF文件 查看货源
内容描述: EC 105ΣC使用寿命长7.000 - 小型化12.000h最高的纹波电流(径向) [EC 105∑C Long Lifetime 7.000 - 12.000h Highest Ripple Currents Miniaturized(Radial)]
分类和应用:
文件页数/大小: 4 页 / 900 K
品牌: JIANGHAI [ JIANGHAI EUROPE GMBH ]
 浏览型号CD261XQX的Datasheet PDF文件第2页浏览型号CD261XQX的Datasheet PDF文件第3页浏览型号CD261XQX的Datasheet PDF文件第4页  
CD
261X
QX Series
7 000 - 12 000h at 105°C
· Extra high Ripple Current
· Down sized
· Electronic Ballast, Lighting
CD
11G
GW
125°C
CD
261X
QX
highest currents
CD
261
LK
longest life
CD
262
QM
Item
Operating Temperature Range (°C)
Voltage Range (V)
Capacitance Range (µF)
Capacitance Tolerance (20°C, 120Hz)
Leakage Current (µA)
Characteristics
-25 ~ +105
160 ~ 450
1,0 ~ 220
± 20%
After 1 minute at 20°C application of rated voltage, leakage current is not more than 0,04CV + 100.
C: Nominal Capacitance (µF) V: Rated Voltage (V)
Rated Voltage (V)
160
200
0,10
20
0
00
0,12
0
Radial
Dissipation Factor (20°C, 120Hz)
Tanδ(max)
Stability at Low Temperature
(Impedance Ratio at 120Hz)
Rated Voltage (V)
160
200
3
20
0
00
6
0
Z
-25°C
/
Z
+20°C
Useful Life
Ø
Ø
Ø
Ø
10x12, : 7 000h
10x16 ~
: 10 000h
>100 000h
10x20
≥ 12
: 12 000h
Load Life
Ø 10x12,5
: 5 000h
Ø 10x16 ~
: 8 000h
Ø 10x20
Ø ≥ 12
: 10 000h
Not more than
specified value
Within ± 30% of initial
value
Not more than 300%
of specified value
U
R
I
R
105°C
guaranteed
Endurance Test
Ø 10x12,5 : 4 000h
Ø 10x16 ~
: 6 000h
Ø 10x20
Ø ≥ 12
: 8 000h
Not more than
specified value
Within ± 20% of initial
value
Shelf Life
Lifetime
1 000h
Not more than specified
value
Within ± 20% of initial
value
Leakage Current
Capacity Change
Dissipation Factor
Condition:
Applied Voltage
Applied Current
Applied Temperature
Failure Rate Level
Not more than specified value
Within ± 50% of initial value
Not more than 500% of specified value
Not more than 200% of Not more than 200% of
specified value
specified value
U
R
I
R
= 0
105°C
U
R
= 0
I
R
= 0
105°C
After test:
U
R
to be applied
for 30min
>24h before
measurement
U
R
I
R
105°C
≤ 1% Failure Rate
U
R
1,6 x I
R
50°C
≤ 1% Failure Rate
Multiplier for Ripple Current
Frequency Coefficient
2.5
Lifetime Diagram
50Hz
0,35
120Hz
0,50
1kHz
0,85
10kHz
0,90
100kHz
1,00
Frequency
Coefficient
I
A
–––
2.0
CD
261X
QX Series
I
R
1.5
1.0
0.5
X32
Lifetime
Multiplier
X16
X8
X4
X2
X1
0.0
40
50
60
70
80
90
100
110
TA
(˚C)
I
A
= actual ripple current at 100kHz, I
R
= rated ripple current at 100kHz, 105°C
Multiplier of Useful Life as a function of ambient temperature and ripple current load