3000-FL SERIES
3
Table 1: Absolute Maximum Ratings
Parameter
Operating case temperature
Storage temperature
LD submount temperature
LD reverse voltage
LD forward current
LD current transient
LD reverse current
PD reverse voltage
PD forward current
Electrostatic discharge (ESD)
TEC current
TEC voltage
Atmospheric pressure
Relative humidity
Lead soldering time
Symbol
T
op
T
stg
T
LD
V
r
I
f_max
Test Condition
-
2000 hours
-
-
Unlimited time
1 µs maximum
-
-
-
C = 100 pF, R = 1.5
Ω,
human body model
-
-
Storage
Operating
Non condensing
260°C
Minimum
-20°C
-40°C
0°C
-
-
-
-
-
-
-
-
-
-
-
5%
-
Maximum
75°C
85°C
50°C
2.5 V
1400 mA
1500 mA
10 µA
20 V
10 mA
1000 V
4.0 A
4.5 V
11 kPa
58 kPa
95%
10 seconds
V
PD
I
PD
V
ESD
I
TEC
V
TEC
R
H
Note: Absolute maximum ratings are the maximum stresses that may be applied to the pump module for short periods of time without causing damage. Stresses in excess of the absolute maximum ratings
can permanently damage the device. Exposure to absolute maximum ratings for extended periods, or exposure to more than one absolute maximum rating simultaneously may adversely affect device
reliability.
Table 2: Operating Parameters
(BOL, T
case
= 0 to 75°C, T
LD
= 25°C, -50 dB reflection, unless noted otherwise)
Product
Code
Maximum
Operating
Power
P
op
(mW)
1,3
Maximum
Operating
Current
I
op
(mA)
Maximum
1
1000
1020
1060
1100
1150
1200
1250
1250
1250
Minimum
Kink-Free
Power
P
max
(mW)
2
Kink-Free
Current
I
max
(mA)
3
Maximum
2
30-xxxx-500-FL
30-xxxx-520-FL
30-xxxx-540-FL
30-xxxx-560-FL
30-xxxx-580-FL
30-xxxx-600-FL
30-xxxx-620-FL
30-xxxx-640-FL
30-xxxx-660-FL
450
460
480
500
520
540
560
580
600
500
520
540
560
580
600
620
640
660
1100
1150
1200
1250
1300
1350
1400
1400
1400
1. The maximum operating power (P
op
) will be achieved at a device-specific maximum operating current (I
op
). The individual value of I
op
is noted on the hardcopy data sheet shipped with the device.
All values of I
op
are limited by the maximum value listed in Table 2.
2. The module is kink-free up to a minimum kink-free power (P
max
) that the module will achieve at a device-specific kink-free current (I
max
). The individual value of I
max
is noted on the hardcopy data sheet
shipped with the device. All values of I
max
are limited by the maximum value listed in Table 2.
3. The pump laser shall never be operated at a power higher than the P
op
throughout its lifetime. At beginning of life (BOL), the operating current shall never be higher than the device-specific I
op
that is
noted on the hardcopy data sheet shipped with the device. At end of life (EOL), the operating current shall never be higher than the device-specific I
max
that is noted on the hardcopy data sheet shipped
with the device.