2900 SERIES PUMPS
3
Absolute Maximum Ratings
Parameter
Operating case temperature
Storage temperature
Laser operating temperature
LD reverse voltage
LD forward current
LD reverse current
PD reverse voltage
PD forward current
Electrostatic discharge (ESD)
Cooler current
TEC voltage
Axial pull force
Side pull force
Fiber bend radius
Atmospheric pressure
Storage
Operating
Relative humidity
Lead soldering time
Symbol
T
op
T
stg
T
LD
V
r
I
f_max
V
PD
I
PF
V
ESD
I
C
V
C
Test Condition
-
2000 hours
-
-
48 hours maximum
-
-
-
C = 100 pF, R = 1.5
Ω,
human body model
-
-
3 x 10 seconds
3 x 10 seconds
-
Minimum
-5 °C
-40 °C
0 °C
-
-
-
-
-
-
-
-
-
-
16 mm
-
-
5%
-
Maximum
75 °C
85 °C
50 °C
2.5 V
1100 mA
10 µA
20 V
10 mA
1000 V
4A
4.5 V
5N
2.5 N
-
11 kPa
58 kPa
95%
10 seconds
R
H
Non condensing
260 °C
Note: Each device is rated to a maximum kink-free current (I
max
), provided on the individual datasheet. This is the maximum current under which the device will perform itsintended function. Operation
above I
max
, and up to the absolute maximum rating, may result in poor device performance, and degrade device reliability. Long-termoperation above Imax may lead to early device failure.
Operating Parameters
Product Code
Operating Power
Pop (mW)
280
290
300
310
315
325
340
360
380
400
410
430
450
Operating Current
Iop (mA)
555
575
595
615
625
645
680
720
760
805
840
875
900
Kink-Free Power
Pmax (mW)
310
320
330
340
350
360
380
400
420
440
460
480
500
Kink-Free Current
Imax (mA)
615
635
655
680
700
720
760
805
855
910
950
985
1000
29-xxxx-310
29-xxxx-320
29-xxxx-330
29-xxxx-340
29-xxxx-350
29-xxxx-360
29-xxxx-380
29-xxxx-400
29-xxxx-420
29-xxxx-440
29-xxxx-460
29-xxxx-480
29-xxxx-500